Sign in

CR-2 · Rural commercial district CR-2 (within rural centers)

Clark County, WA · CCC 40.210 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached dwellings
Home✓1 ADU✓2
————
Assisted living facilities————
Home✓1 ADU—
Adult family homes————
Home✓3 ADU—
Residential care homes————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit CCC Table 40.210.050-2
Minimum lot widthNo limit CCC Table 40.210.050-2
Minimum lot depthNo limit CCC Table 40.210.050-2
Maximum residentsNot set CCC 40.210.050(C)
6 persons CCC 40.100.070
for Adult family homes (group living)3
10 persons CCC 40.100.070
for Residential care homes (group living)

3. Building standards

StandardValueExceptions
Front setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC Table 40.210.050-3; 40.320.010
Side setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC Table 40.210.050-3; 40.320.010
Street side setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC Table 40.210.050-3; 40.320.010
Rear setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC Table 40.210.050-3; 40.320.010
Maximum heightNo limit CCC Table 40.210.050-3
Maximum lot coverageMaximum determined by compliance with screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, the Stormwater and Erosion Control Ordinance (Chapter 40.386), and all other applicable standards. CCC Table 40.210.050-3
Minimum parking2 spaces per unit CCC Table 40.340.010-4(A)(1); 40.210.050(C)(3)
1 ÷ 3 spaces per unit CCC Table 40.340.010-4(A)(8); 40.260.190(D)(1)
for Assisted living facilities (group living)1
residents ÷ 3 spaces CCC 40.260.190(C)(2)
for Adult family homes (group living)3
Minimum open space15% CCC 40.210.050(C)(4)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit CCC 40.260.210(B)(1)(a)

Building

StandardValueExceptions
Front setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
Side setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
Rear setback
  • Pursuant to buffering and screening standards contained in Chapter 40.320, Table 40.320.010-1.4 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
  • Pursuant to the screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, plus an additional ½ foot for each foot the building exceeds 20 feet in height to a maximum setback requirement of 40 feet. Buildings in excess of 20 feet may be stepped.5 CCC 40.260.210(B)(1); Table 40.210.050-3; 40.320.010
Maximum heightNo limit CCC 40.260.210(B)(1); Table 40.210.050-3
Attached to the main houseNot required CCC 40.260.210(B)(1)(c)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat CCC 40.540.030(C)(2) A up to 4 CCC 40.540.030(A); 40.100.070 —
Minimum lot size
No limit CCC Table 40.210.050-2
Minimum lot width
No limit CCC Table 40.210.050-2
Minimum lot depth
No limit CCC Table 40.210.050-2
Subdivision CCC 40.540.040(B)(2) H 5 or more CCC 40.100.070 —
Minimum lot size
No limit CCC Table 40.210.050-2
Minimum lot width
No limit CCC Table 40.210.050-2
Minimum lot depth
No limit CCC Table 40.210.050-2
Exempt division (20 acres or 1/32 section) CCC 40.540.020(B)(4)(b) ✓ — —
Minimum lot size
871,200 sq ft CCC 40.540.020(B)(4)(b)
Minimum lot width
No limit CCC Table 40.210.050-2
Minimum lot depth
No limit CCC Table 40.210.050-2

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential use is integrated with the predominant commercial use of the site, occupies less than 50% of the project floor area, and is built following or with the commercial part
  2. All of these are true:
    • The residential use is integrated with the predominant commercial use of the site, occupies less than 50% of the project floor area, and is built following or with the commercial part
    • The temporary dwelling is for a person listed in Section 40.260.210(A): a caregiver or care receiver, a farm caretaker or hired hand, a low-income relative over 62, or (forest and agricultural districts only) a relative or a purchaser where the seller kept a life estate
    • Any of these is true:
      • Lot area is at least 43,560 sf
      • The parcel can comply with the residential density standards of the zone with the temporary dwelling added
  3. All of these are true:
    • The adult family home is in an existing single-family dwelling or duplex
    • The residential use is integrated with the predominant commercial use of the site, occupies less than 50% of the project floor area, and is built following or with the commercial part
  4. None of these is true:
    • The setback is from a lot line adjacent to a residential district
  5. The setback is from a lot line adjacent to a residential district