BP · Business Park (BP) District
Clark County, WA · CCC 40.230 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Nursing or convalescent homes | — | — | — | — | Home✓ ADU— |
| Assisted living facilities | — | — | — | — | Home✓ ADU— |
| Residential care facilities | — | — | — | — | |
| Residential care homes | — | — | — | — | |
| Congregate care facilities | — | — | — | — | HomeA ADU— |
| Staffed residential homes | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 217,800 sq ft CCC Table 40.230.085-2; Table 40.230.085-2(note 4); 40.230.085(D)(1); 40.230.085(D)(1)(a) | |
| Minimum lot width | No limit CCC Table 40.230.085-2 | |
| Maximum residents | Not set CCC 40.100.070; 40.230.085 | 10 persons CCC 40.100.070
for Residential care homes (group living)1 6 persons CCC 40.100.070
for Staffed residential homes (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Street side setback | ||
| Rear setback | ||
| Maximum height | 100 ft CCC Table 40.230.085-2(note 2) | |
| Maximum lot coverage | Maximum determined by compliance with screening and buffering standards contained in Chapter 40.320, Table 40.320.010-1, the Stormwater and Erosion Control Ordinance (Chapter 40.386), and all other applicable standards. CCC Table 40.230.085-2 | |
| Minimum parking | beds in the project ÷ 3 spaces CCC 40.230.085(D)(1)(e); 40.260.190(E)(1); Table 40.340.010-4(C)(2) | main dwelling units on the lot ÷ 3 spaces CCC 40.230.085(D)(1)(e); 40.260.190(D)(1); Table 40.340.010-4(A)(8)
for Assisted living facilities (group living) for Residential care facilities (group living)1 2 spaces per unit CCC 40.230.085(D)(1)(e); Table 40.340.010-4(A)(1)
for Residential care homes (group living)1 Where Table 40.340.010-4 does not list the parking requirements for a proposed use, the responsible official shall determine the minimum parking requirements for the use, based on requirements in Table 40.340.010-4 for other similar uses, if any, or on substantial evidence of parking needs for similar uses in other, similar locations. CCC 40.230.085(D)(1)(e); 40.340.010(B)(4)
for Congregate care facilities (group living) 1 × employees on the largest shift spaces CCC 40.230.085(D)(1)(e); 40.260.205(C)(3)
for Staffed residential homes (group living)2 |
| Minimum open space | 15% CCC Table 40.230.085-2; 40.230.085(D)(1)(f); 40.230.085(D)(3); 40.230.085(D)(3)(d); 40.230.085(D)(3)(d)(6) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat CCC 40.540.030 | A | up to 9 CCC 40.100.070; 40.540.030 | — | Minimum lot size 217,800 sq ft CCC Table 40.230.085-2; Table 40.230.085-2(note 4); 40.230.085(D)(1); 40.230.085(D)(1)(a) Minimum lot width No limit CCC Table 40.230.085-2 |
| Subdivision CCC 40.540.040(B)(2) | H | 10 or more CCC 40.100.070; 40.540.040 | — | Minimum lot size 217,800 sq ft CCC Table 40.230.085-2; Table 40.230.085-2(note 4); 40.230.085(D)(1); 40.230.085(D)(1)(a) Minimum lot width No limit CCC Table 40.230.085-2 |
| Exempt division (20 acres or 1/32 section) CCC 40.540.020(B)(4)(b) | ✓ | — | — | Minimum lot size 871,200 sq ft CCC 40.540.020(B)(4)(b) |
| Binding site plan CCC 40.520.040(C)(1)(a); 40.520.040(B)(2)(c) | A12 | Maximum lots Not set CCC 40.520.040(C) |
— | Minimum lot size 217,800 sq ft CCC Table 40.230.085-2; Table 40.230.085-2(note 4); 40.230.085(D)(1); 40.230.085(D)(1)(a) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Not all of these are true:
- The residential care facility or home houses justice offenders and/or residents subject to partial or full confinement
- The property is within 300 feet (property line to property line) of an existing school or licensed commercial day care center
- None of these is true:
- Another staffed residential home is within a one-mile radius of the site
- Building height is at most 36
- Building height is more than 36
- The side or rear lot line abuts a railroad right-of-way or spur track
- All of these are true:
- The site adjoins (abuts) a residential zoning district or residentially zoned property
- Building height is at most 36
- The side or rear lot line abuts a railroad right-of-way or spur track
- All of these are true:
- Building height is at most 36
- The side or rear lot line abuts a railroad right-of-way or spur track
- The site adjoins (abuts) a residential zoning district or residentially zoned property
- All of these are true:
- Building height is more than 36
- The side or rear lot line abuts a railroad right-of-way or spur track
- Age group of the residents served by the residential care facility is under_12
- Age group of the residents served by the residential care facility is age_12_to_17
- Age group of the residents served by the residential care facility is age_18_plus
- The land is divided for sale or for lease of commercially or industrially zoned property (RCW 58.17.040(4))