Sign in

MX · MX (Mixed Use)

Cheney, WA · CMC 21.32 · Official code

By right: 1 unit, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single Dwelling, Attached
Home✓1 ADU—
————
Live/work Unit
Home✓ ADU—
————
Townhouse——
Home✓1 ADU—
Home✓1 ADU—
—
Multi-Dwelling Units——
Home✓1 ADU—
Home✓1 ADU—
—
Senior Housing———
Home✓ ADU—
—
Household Living———
Home✓ ADU—
—
Group Living————
HomeH ADU—
Transitional Housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size1,600 sq ft CMC 21.32.040(B)
Minimum lot width20 ft CMC 21.32.040(B)
Minimum lot depth80 ft CMC 21.32.040(B)
Maximum densityNot set CMC 21.32.040(B)
21 units per acre, a fraction of 0.5 or more rounds up, on the net lot area CMC 21.32.040(E)(10); 21.24.020(A); 21.24.040(A); 21.10.020
for Multi-Dwelling Units (3, 4+ units)1; Senior Housing (4+ units); Household Living (4+ units)
Maximum sleeping unitsNot set CMC 21.32.040(B)
2 sleeping units CMC 21.32.030(B) note 16
for Transitional Housing (group living)

3. Building standards

StandardValueExceptions
Maximum front setback10 ft CMC 21.32.040(B)
Side setback0 ft CMC 21.32.040(B)
Street side setback0 ft CMC 21.32.040(B)
Rear setback0 ft CMC 21.32.040(B)
Building separationNo limit CMC 21.32.040(B)
Maximum height
  • 35 ft2 CMC 21.32.040(B)
  • 45 ft3 CMC 21.32.040(B); 21.32.040(E)(11)
  • 35 ft4 CMC 21.32.040(B)
Maximum lot coverage80% CMC 21.32.040(B)
Minimum parking2 spaces per unit CMC 21.32.060; 21.40.020(1)
the largest of 1, bedrooms in one unit spaces per unit CMC 21.32.060; 21.40.020(1)
for Multi-Dwelling Units (3, 4+ units)1; Household Living (4+ units)
0.5 × bedrooms in one unit spaces per unit CMC 21.32.060; 21.40.020(1)
for Senior Housing (4+ units)
1 space per resident CMC 21.32.060; 21.40.020(1)
for Group Living (group living)
beds in the project ÷ 3 spaces CMC 21.32.060; 21.40.020(1)
for Transitional Housing (group living)
Minimum open space5% CMC 21.32.040(B)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat CMC 22.26.110(a) A up to 4 CMC 22.08.005 —
Minimum lot size
1,600 sq ft CMC 21.32.040(B)
Minimum lot width
20 ft CMC 21.32.040(B)
Minimum lot depth
  • 120 ft5 CMC 22.24.040(6)
  • 80 ft6 CMC 21.32.040(B)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Subdivision CMC 22.12.020(a); 22.04.090 H 5 or more CMC 22.08.005 —
Minimum lot size
1,600 sq ft CMC 21.32.040(B)
Minimum lot width
20 ft CMC 21.32.040(B)
Minimum lot depth
  • 120 ft5 CMC 22.24.040(6)
  • 80 ft6 CMC 21.32.040(B)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Binding site plan CMC 22.27.030(a) A up to 3 CMC 22.27.030(a) —
Minimum lot size
1,600 sq ft CMC 21.32.040(B)
Minimum lot width
20 ft CMC 21.32.040(B)
Minimum lot depth
  • 120 ft5 CMC 22.24.040(6)
  • 80 ft6 CMC 21.32.040(B)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040
Binding site plan CMC 22.27.030(b) H 5 or more CMC 22.27.030(b) —
Minimum lot size
1,600 sq ft CMC 21.32.040(B)
Minimum lot width
20 ft CMC 21.32.040(B)
Minimum lot depth
  • 120 ft5 CMC 22.24.040(6)
  • 80 ft6 CMC 21.32.040(B)
Minimum frontage
Not set CMC 22.24.040(1)
Maximum units per lot
Not set CMC 22.24.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Any of these is true:
      • The residential units are located above or below the ground floor (street level) of the structure
      • The residential units are located off of an alley
    • Any of these is true:
      • None of these is true:
        • The residential units are part of a mixed-use structure
      • All of these are true:
        • The residential units are located above or below the ground floor (street level) of the structure
        • The residential units are located off of an alley
  2. The portion of the structure is within 50 feet of a residential zoning district line
  3. All of these are true:
    • Residential use represents 100% of the floor area exceeding 35 feet
    • Any of these is true:
      • At least 20 percent of the building floor area is devoted to commercial uses
      • At least 25 percent of the site is devoted to commercial uses
    None of these is true:
    • The portion of the structure is within 50 feet of a residential zoning district line
  4. All of these are true:
    • Not all of these are true:
      • Residential use represents 100% of the floor area exceeding 35 feet
      • Any of these is true:
        • At least 20 percent of the building floor area is devoted to commercial uses
        • At least 25 percent of the site is devoted to commercial uses
    None of these is true:
    • The portion of the structure is within 50 feet of a residential zoning district line
  5. The residential lot fronts on a community arterial
  6. None of these is true:
    • The residential lot fronts on a community arterial