R4 · Low-density residential district (R:4)
Centralia, WA · CMC 20.21; 20.11.010 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | — | — | — | — | |
| Manufactured home | — | — | — | — | |
| Duplex | — | — | — | — | |
| Twinhome | — | — | — | — | |
| Triplex | — | — | — | — | |
| Townhouse development | — | — | — | ||
| Fourplex | — | — | — | — | |
| Planned unit development (PUD) | — | — | — | — | |
| Adult family home with 8 or fewer residents | — | — | — | — | |
| Assisted living facility | — | — | — | — | HomeH ADU— |
| Boarding houses, hostel, etc. | — | — | — | — | |
| Emergency housing/homeless housing (indoors only) | — | — | — | — | |
| Emergency shelter for domestic violence | — | — | — | — | |
| Foster home | — | — | — | — | |
| Nursing home/convalescent care facility/long-term care facility | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set CMC 20.21 | 4 units CMC 20.06.284.5
for Fourplex (4+ units) |
| Minimum units | 4 units CMC 20.06.284.5 | 3 units CMC 20.61.020(A)
for Townhouse development (4+ units) Not set CMC 20.21
for Planned unit development (PUD) (4+ units) |
| Minimum lot size | 10,890 sq ft CMC 20.21.050 | 1,600 × main dwelling units on the lot sq ft CMC 20.61.040(B)
for Townhouse development (3, 4+ units) 13,000 sq ft CMC 20.21.050
for Fourplex (4+ units) 4,000 sq ft CMC 20.60.100(A)
for Planned unit development (PUD) (4+ units) |
| Minimum lot width | 40 ft CMC 20.21.050 | Not set CMC 20.60.050(A)(2); 20.60.100
for Planned unit development (PUD) (4+ units) |
| Minimum frontage | ||
| Minimum density | Not set CMC 20.21.050 | 0 units per acre CMC 20.21.050
for Single-family dwelling (1 unit); Manufactured home (1 unit)2; Duplex (2 units); Twinhome (2 units); Triplex (3 units); Townhouse development (3, 4+ units); Fourplex (4+ units); Planned unit development (PUD) (4+ units) |
| Maximum density | 4 units per acre CMC 20.21.050 | for Townhouse development (3, 4+ units) for Planned unit development (PUD) (4+ units) Not set CMC 20.21.050
|
| Minimum development size | Not set CMC 20.21.050 | 87,120 sq ft CMC 20.60.080
for Planned unit development (PUD) (4+ units) |
| Maximum residents | Not set CMC 20.11.010(B) | 6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)5 10 persons CMC 20.06.150
for Boarding houses, hostel, etc. (group living)4 9 persons CMC 20.11.010(B)
for Emergency shelter for domestic violence (group living)6 80 persons CMC 20.62.030(A)
for Emergency shelter for domestic violence (group living)7 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft CMC 20.21.060 | 10 ft CMC 20.60.110(B)(1)
for Planned unit development (PUD) (4+ units) |
| Side setback | 5 ft CMC 20.21.060 | |
| Street side setback | 15 ft CMC 20.21.060 | Not set CMC 20.60.110
for Planned unit development (PUD) (4+ units) |
| Rear setback | 25 ft CMC 20.21.060 | 15 ft CMC 20.61.040(F)
for Townhouse development (3, 4+ units) 10 ft CMC 20.60.110(B)(6)
for Planned unit development (PUD) (4+ units) |
| Building separation | Not set CMC 20.21.060 | 10 ft CMC 20.61.040(I)
for Townhouse development (3, 4+ units); Planned unit development (PUD) (4+ units) |
| Maximum height | 35 ft CMC 20.21.070 | |
| Maximum lot coverage | 50% CMC 20.21.050 | |
| Minimum parking | 2 spaces per unit CMC 20.72.030(B); 20.21.090 | The community development department and city engineer shall determine which of the uses is most similar based upon staff experience with various uses and information provided by the applicant CMC 20.72.030(C); 20.21.090
for Adult family home with 8 or fewer residents (group living); Foster home (group living) (main dwelling units on the lot ÷ 3) + (main dwelling units on the lot ÷ 5) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
for Assisted living facility (group living) 1 space per sleeping unit CMC 20.72.030(C); 20.21.090
for Boarding houses, hostel, etc. (group living)4 (0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.21.090
(residents ÷ 3) + employees on the largest shift spaces CMC 20.72.030(C); 20.21.090
for Nursing home/convalescent care facility/long-term care facility (group living) |
| Minimum open space | Not set CMC 20.50.050(A) | 30% CMC 20.60.140(A)(1)
for Planned unit development (PUD) (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 20.21.040(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft CMC 20.21.040(D)(5) | |
| Side setback | 5 ft CMC 20.21.040(D)(5) | |
| Rear setback | 5 ft CMC 20.21.040(D)(5) | |
| Maximum height | ||
| Minimum parking | ||
| Attached to the main house | Not required CMC 20.21.040(A) | |
| Owner lives on site | Not required CMC 20.21.040(E) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) | A | up to 9 CMC 19.04.020; 19.16.010(A) | — | Minimum lot size
Minimum lot width 40 ft CMC 20.21.050 |
| Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) | H | 5 or more CMC 19.04.020; 19.12.010(A) | — | Minimum lot size
Minimum lot width 40 ft CMC 20.21.050 |
| Large lot subdivision CMC 19.18.010(D) | A | Maximum lots Not set CMC 19.18.010(A) |
— | Minimum lot size 217,800 sq ft CMC 19.18.010(A) Minimum lot width 40 ft CMC 20.21.050 |
| Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) | A | Maximum lots which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C) |
— | Minimum lot size
Minimum lot width 40 ft CMC 20.21.050 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
- Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
- Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
- The manufactured home has not been previously sited and used for residential or commercial purposes (except as a display model)
- All of these are true:
- The manufactured home has not been previously sited and used for residential or commercial purposes (except as a display model)
- Development at the ADU location is restricted under federal, state, or local law because of physical proximity to on-site sewage system infrastructure
- Development at the ADU location is restricted under federal, state, or local law because of physical proximity to critical areas (CMC Title 16) or their buffer areas
- Development at the ADU location is restricted under federal, state, or local law because of other unsuitable physical characteristics of the property
- All of these are true:
- The residence is owner-occupied (the fee owner, contract purchaser or life tenant resides there more than eight months per calendar year)
- The boarding house or hostel is located in the principal residence on the premises, not in another structure
- The use does not require exterior structural alterations of the residence
- All of these are true:
- Residents is at most 6
- The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
- All of these are true:
- Residents is less than 10
- The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
- All of these are true:
- Residents is at least 10
- The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
- None of these is true:
- The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
- The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
- None of these is true:
- The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
- None of these is true:
- The project gets a townhouse density bonus approved by the site plan review committee
- The project gets a townhouse density bonus approved by the site plan review committee
- None of these is true:
- The project gets a PUD density bonus approved by the city council
- The project gets a PUD density bonus approved by the city council
- Main dwelling units on the lot is more than 5
- Main dwelling units on the lot is at most 5
- The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
- None of these is true:
- The accessory dwelling unit is in an accessory building (detached from the primary dwelling)
- The accessory dwelling unit is within one-half mile walking distance of a major transit stop
- None of these is true:
- The accessory dwelling unit is within one-half mile walking distance of a major transit stop
- All of these are true:
- The parcel is unplatted
- Lot area is less than 43,560 sf
- Not all of these are true:
- The parcel is unplatted
- Lot area is less than 43,560 sf