Sign in

M1 · Light industrial district (M-1)

Centralia, WA · CMC 20.40; 20.11.030 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live work units—Commercial located on the ground floor, residential units on upper floor(s)
Home✓ ADU—
————
Adult family home with 8 or fewer residents————
Home✓ ADU—
Boarding houses, hostel, etc.————
HomeH1 ADU—
Emergency housing/homeless housing (indoors only)————
Home✓2 ✓3 ADU—
Emergency shelter for homeless housing (indoors only)————
Home✓4 ADU—
Emergency shelter for domestic violence————
Home✓5 ✓6 ADU—
Enhanced services facility————
HomeH7 ADU—
Permanent supportive housing————
Home✓4 ADU—
Residential treatment facility————
HomeH8 ADU—
Transitional housing————
Home✓4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit CMC 20.40.050(A)
Minimum lot widthNo limit CMC 20.40.050(B)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Maximum residentsNot set CMC 20.11.030(B)
6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)2
10 persons CMC 20.06.150
for Boarding houses, hostel, etc. (group living)1
80 persons CMC 20.62.030(A)
for Emergency housing/homeless housing (indoors only) (group living)3; Emergency shelter for homeless housing (indoors only) (group living)4; Emergency shelter for domestic violence (group living)6
9 persons CMC 20.11.030(B)
for Emergency shelter for domestic violence (group living)5

3. Building standards

StandardValueExceptions
Front setback20 ft CMC 20.40.050(E)
Side setbackSide yard setback: as currently required by the currently adopted building code of the city of Centralia; CMC 20.40.050(C)
Street side setback15 ft CMC 20.40.050(G)
Rear setbackRear yard setback: as currently required by the currently adopted building code of the city of Centralia; CMC 20.40.050(D)
Building separation10 ft CMC 20.40.050(F)
Maximum heightMaximum Building Height. Height limits will be imposed if necessary to prevent detrimental effects upon the surrounding properties. CMC 20.40.060(A)
Minimum parkingThe community development department and city engineer shall determine which of the uses is most similar based upon staff experience with various uses and information provided by the applicant CMC 20.72.030(C); 20.40.070
The total requirements for off-street parking shall be the sum of the requirements for the several uses computed separately CMC 20.72.030(C); 20.40.070
for Live work units—Commercial located on the ground floor, residential units on upper floor(s) (1 unit)
1 space per sleeping unit CMC 20.72.030(C); 20.40.070
for Boarding houses, hostel, etc. (group living)1
2 spaces per unit CMC 20.72.030(B); 20.40.070
for Emergency housing/homeless housing (indoors only) (group living)2
(the largest of 1.5 × main dwelling units on the lot, 0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.40.070
for Emergency housing/homeless housing (indoors only) (group living)3
(0.5 × (floor area of all units ÷ 1,000)) + employees on the largest shift spaces CMC 20.72.030(B); 20.40.070
for Emergency shelter for homeless housing (indoors only) (group living)4; Emergency shelter for domestic violence (group living)5; Emergency shelter for domestic violence (group living)6
1.5 spaces per unit CMC 20.72.030(B); 20.40.070
for Permanent supportive housing (group living)4; Transitional housing (group living)4
Minimum open space5% CMC 20.40.080; 20.50.050(C)(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) A up to 9 CMC 19.04.020; 19.16.010(A) —
Minimum lot size
No limit CMC 20.40.050(A)
Minimum lot width
No limit CMC 20.40.050(B)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) H 5 or more CMC 19.04.020; 19.12.010(A) —
Minimum lot size
No limit CMC 20.40.050(A)
Minimum lot width
No limit CMC 20.40.050(B)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Large lot subdivision CMC 19.18.010(D) A
Maximum lots
Not set CMC 19.18.010(A)
—
Minimum lot size
217,800 sq ft CMC 19.18.010(A)
Minimum lot width
No limit CMC 20.40.050(B)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) A
Maximum lots
which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C)
—
Minimum lot size
No limit CMC 20.40.050(A)
Minimum lot width
No limit CMC 20.40.050(B)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Binding site plan CMC 19.28.070; 19.28.080; 20.02.040(D) H
Maximum lots
Not set CMC 19.28.030
—
Minimum lot size
Design and Development Requirements. Design and development standards of this title will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this chapter. CMC 19.28.050(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The residence is owner-occupied (the fee owner, contract purchaser or life tenant resides there more than eight months per calendar year)
    • The boarding house or hostel is located in the principal residence on the premises, not in another structure
    • The use does not require exterior structural alterations of the residence
  2. All of these are true:
    • Residents is at most 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  3. All of these are true:
    • Residents is more than 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  4. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  5. All of these are true:
    • Residents is less than 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  6. All of these are true:
    • Residents is at least 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  7. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
    • The site is within 1,000 feet of public parks, playgrounds, recreation/community centers, libraries, child care centers, schools, game arcades, or public transit centers
  8. None of these is true:
    • The site is less than 1,000 feet from another residential treatment facility
  9. The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  10. None of these is true:
    • The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)