Sign in

C3 · Core commercial district (C-3)

Centralia, WA · CMC 20.24; 20.11.020 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live work units—Commercial located on the ground floor, residential units on upper floor(s)
Home✓ ADU—
————
Single-family dwelling
Home✓1 ADU—
————
Duplex—
Home✓1 ADU—
———
Triplex——
Home✓1 ADU—
——
Fourplex———
Home✓1 ADU—
—
Multiple-family dwelling———
Home✓1 H2 ADU—
—
Adult family home with 8 or fewer residents————
Home✓ ADU—
Dormitory for students————
Home✓ ADU—
Emergency housing/homeless housing (indoors only)————
Home✓3 H4 ADU—
Emergency shelter for homeless housing (indoors only)————
HomeH5 ADU—
Emergency shelter for domestic violence————
Home✓6 ✓7 ADU—
Foster home————
Home✓8 ADU—
Nursing home/convalescent care facility/long-term care facility————
HomeH ADU—
Permanent supportive housing————
Home✓5 ADU—
Transitional housing————
Home✓5 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set CMC 20.24
4 units CMC 20.06.284.5
for Fourplex (4+ units)1
Minimum units4 units CMC 20.06.284.5
5 units CMC 20.06.285
for Multiple-family dwelling (4+ units)1
16 units CMC 20.24.020(C)(1)
for Multiple-family dwelling (4+ units)2
Minimum lot sizeNo limit CMC 20.24.055(A)
Minimum lot widthNo limit CMC 20.24.055(A)
Minimum lot depthNo limit CMC 20.24.055(A)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Maximum residentsNot set CMC 20.11.020(B)
6 persons CMC 20.06.095
for Adult family home with 8 or fewer residents (group living); Emergency housing/homeless housing (indoors only) (group living)3
80 persons CMC 20.62.030(A)
for Emergency housing/homeless housing (indoors only) (group living)4; Emergency shelter for homeless housing (indoors only) (group living)5; Emergency shelter for domestic violence (group living)7
9 persons CMC 20.11.020(B)
for Emergency shelter for domestic violence (group living)6

3. Building standards

StandardValueExceptions
Front setbackNo limit CMC 20.24.055(B)
Maximum front setback10 ft CMC 20.24.055(B)
Side setbackNo limit CMC 20.24.055(B)
Street side setbackNo limit CMC 20.24.055(B)
Rear setbackNo limit CMC 20.24.055(B)
Maximum height100 ft CMC 20.24.090
Minimum parking0 spaces per unit CMC 20.72.005; 20.24.080
Minimum open space15% CMC 20.50.050(B)(1)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision CMC 19.16.010(D); 19.16.020(B)(4) A up to 9 CMC 19.04.020; 19.16.010(A) —
Minimum lot size
No limit CMC 20.24.055(A)
Minimum lot width
No limit CMC 20.24.055(A)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Subdivision CMC 19.12.050(A); 19.12.060; 20.02.040(D) H 5 or more CMC 19.04.020; 19.12.010(A) —
Minimum lot size
No limit CMC 20.24.055(A)
Minimum lot width
No limit CMC 20.24.055(A)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Large lot subdivision CMC 19.18.010(D) A
Maximum lots
Not set CMC 19.18.010(A)
—
Minimum lot size
217,800 sq ft CMC 19.18.010(A)
Minimum lot width
No limit CMC 20.24.055(A)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Boundary line adjustment CMC 19.20.020(D); 19.20.030(B) A
Maximum lots
which does not create an additional lot, tract, parcel, building site, or division, nor creates any lot, tract, parcel, building site, or division which contains insufficient area or dimension to meet the minimum requirements for width or area for a building site CMC 19.04.020; 19.20.020(C)
—
Minimum lot size
No limit CMC 20.24.055(A)
Minimum lot width
No limit CMC 20.24.055(A)
Minimum frontage
  • 20 ft9 CMC 19.32.030(B)
  • Not set10 CMC 19.32.030(A)
Binding site plan CMC 19.28.070; 19.28.080; 20.02.040(D) H
Maximum lots
Not set CMC 19.28.030
—
Minimum lot size
Design and Development Requirements. Design and development standards of this title will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this chapter. CMC 19.28.050(B)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All dwelling units are located above the first floor
  2. None of these is true:
    • All dwelling units are located above the first floor
    • The building is located on a collector or arterial roadway
  3. All of these are true:
    • Residents is at most 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  4. All of these are true:
    • Residents is more than 6
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  5. None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  6. All of these are true:
    • Residents is less than 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  7. All of these are true:
    • Residents is at least 10
    None of these is true:
    • The parcel is closer than 1,500 feet to another supportive housing facility (not co-located on the same property)
  8. Residents is at least 7
  9. The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)
  10. None of these is true:
    • The lot is a flag lot (a lot not meeting minimum frontage requirements, with access to the public road by a private easement or driveway)