MX · Mixed Use
Camas, WA · CMC 18.05.050(K); 18.07.030; 18.09.030; 18.24 · Official code
By right: 1 unit, 2 units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | Home✓ ADU✓ | — | — | — | — |
| Designated manufactured home | Home✓ ADU✓ | — | — | — | — |
| Residence accessory to and connected with a business | — | — | — | — | |
| Duplex or two-family dwelling | — | Home✓ ADU✓ | — | — | — |
| Apartment, multifamily development, row houses | — | — | HomeH ADU✓ | HomeH ADU✓ | — |
| Adult family home | — | — | — | — | Home✓ ADU✓ |
| Assisted living | — | — | — | — | Home✓ ADU— |
| Group home | — | — | — | — | Home✓ ADU— |
| Housing for the disabled | — | — | — | — | Home✓ ADU✓ |
| Nursing, rest, convalescent home | — | — | — | — | Home✓ ADU— |
| Retirement home | — | — | — | — | Home✓ ADU— |
| Residential Treatment Facility | — | — | — | — | |
| Sober Living Homes | — | — | — | — | Home✓ ADU✓ |
| Transitional Housing | — | — | — | — | Home✓ ADU— |
| Permanent Supportive Housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 1,800 sq ft CMC 18.09.030 Table 1 | |
| Minimum lot width | No limit CMC 18.09.030 Table 1 | |
| Minimum lot depth | No limit CMC 18.09.030 Table 1 | |
| Maximum density | Not set CMC 18.09.030 Table 1 | 24 units per acre, on the net lot area CMC 18.09.030 Table 1
for Single-family dwelling (1 unit); Designated manufactured home (1 unit); Residence accessory to and connected with a business (1 unit)1; Duplex or two-family dwelling (2 units); Apartment, multifamily development, row houses (3, 4+ units) |
| Maximum residents | Not set CMC 18.03.030 | 6 persons CMC 18.03.030
for Adult family home (group living) 8 persons CMC 18.03.030
for Sober Living Homes (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum front setback | 10 ft CMC 18.09.030 Table 1 note 3 | |
| Side setback | 10 ft CMC 18.09.030 Table 1 | |
| Rear setback | 25 ft CMC 18.09.030 Table 1 | |
| Maximum height | No limit CMC 18.09.030 Table 1 | |
| Maximum lot coverage | ||
| Minimum parking | In case of a use not specifically mentioned in Section 18.11.130 of this chapter, the requirements for off-street parking facilities shall be determined by the city in accordance with a conditional use permit. Such determination shall be based upon the requirements for the most comparable use listed. CMC 18.11.060 | 2 spaces per unit CMC 18.11.130
for Single-family dwelling (1 unit); Designated manufactured home (1 unit); Residence accessory to and connected with a business (1 unit)1; Duplex or two-family dwelling (2 units); Retirement home (group living) for Apartment, multifamily development, row houses (3, 4+ units) (beds in the project ÷ 2) + employees on the largest shift spaces CMC 18.11.130
for Assisted living (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 18.27.040(A) | 1 unit CMC 18.27.040(A)
for Duplex or two-family dwelling (2 units); Apartment, multifamily development, row houses (3, 4+ units) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft CMC 18.27.040(F) | |
| Attached to the main house | Not required CMC 18.27.030(A)-(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision (short plat) CMC 17.09.020; 18.55.030 | A | up to 9 CMC 17.09.010(A) | 24 units per acre, on the net lot area CMC 18.09.030 Table 1 | Minimum lot size 1,800 sq ft CMC 18.09.030 Table 1 Minimum lot width No limit CMC 18.09.030 Table 1 Minimum lot depth No limit CMC 18.09.030 Table 1 |
| Subdivision CMC 17.11.020; 18.55.030 | H | 10 or more CMC 17.11.010 | 24 units per acre, on the net lot area CMC 18.09.030 Table 1 | Minimum lot size 1,800 sq ft CMC 18.09.030 Table 1 Minimum lot width No limit CMC 18.09.030 Table 1 Minimum lot depth No limit CMC 18.09.030 Table 1 |
| Binding site plan CMC 17.15.020; 18.55.030 | A | — | 24 units per acre, on the net lot area CMC 18.09.030 Table 1 | Minimum lot size This land division allows certain zoning standards including, for example, minimum parking, setbacks, landscaping, lot area and lot dimension on the individual lots to be modified provided the standards for the entire center are met. CMC 17.15.010 |
| Unit lot subdivision CMC 17.09.070(A)-(B); 18.27.030(E); 18.55.030Only for: Single-family dwelling, Designated manufactured home, Duplex or two-family dwelling | A | 2 to 9 CMC 18.03.040; CMC 17.09.070(B); 17.09.010(A) | — | Minimum lot size No limit CMC 17.09.070 Maximum lot size No limit CMC 17.09.070 Minimum lot width No limit CMC 17.09.070 Minimum lot depth No limit CMC 17.09.070 Minimum frontage No limit CMC 17.09.070 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The residence is accessory to and connected with a business on the same site
- None of these is true:
- The site is within one thousand feet of a public or private school, public park, public library, another residential treatment facility or a similar use
- All of these are true:
- Building stories is at most 1
- The project provides public art approved by the design review committee
- All of these are true:
- Building stories is at least 2
- The project provides public art approved by the design review committee
- All of these are true:
- Building stories is at most 1
- The project provides public art approved by the design review committee
- All of these are true:
- Building stories is at least 2
- The project provides public art approved by the design review committee
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU's side lot line is along a flanking street of a corner lot
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU's side lot line is along a flanking street of a corner lot
- None of these is true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The rear lot line abuts a public alley
- All of these are true:
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The rear lot line abuts a public alley
- The ADU is detached from the primary dwelling (not an internal conversion or structural addition to it)
- The ADU is located within one-half mile of a major transit stop
- None of these is true:
- The ADU is located within one-half mile of a major transit stop