Sign in

RD-2 · RD-2 subzone of the RD Land Use Zones

Burlington, WA · BMC 17.15 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached dwellings
Home✓ ADU✓1 ✓2 prohibited3
————
Manufactured homes
Home✓ ADU✓1 ✓2 prohibited3
————
Duplex dwellings—
Home✓4 ADU✓5 ✓6
———
Horizontally attached dwellings——
HomeH7 ADU✓8 ✓9
HomeH7 ADU✓8 ✓9
—
Small multiunit buildings——
HomeH7 ADU✓8 ✓9
HomeH7 ADU✓8 ✓9
—
Small boarding houses————
Home✓ ADU✓10 ✓11

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units4 units BMC 17.15.090(J)(8); 17.15.100(F)
Minimum lot size
  • 6,000 sq ft12 BMC 17.15.100(A)(1)(b)
  • Not set13 BMC 17.15.100(A)
  • 6,000 sq ft14 BMC 17.15.100(A)(1)(b)
  • 3,000 sq ft15 BMC 17.15.110(A)
  • Not set13 BMC 17.15.100(A)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Minimum lot width
  • 30 ft12 BMC 17.15.100(A)(2)
  • Not set13 BMC 17.15.100(A)
Minimum lot depth
  • 80 ft12 BMC 17.15.100(A)(3)
  • Not set13 BMC 17.15.100(A)
Maximum sleeping units4 sleeping units BMC 17.01.050

3. Building standards

StandardValueExceptions
Front setback17 ft BMC 17.15.100(B)(1)
  • 17 ft16 BMC 17.15.100(B)(1)
  • 17 ft17 BMC 17.15.110(F)(1)(a)
  • 10 ft18 BMC 17.15.110(F)(1)(b)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Side setback5 ft BMC 17.15.100(B)(3); 17.15.110(F)(4)
Total side setbacks
  • 15 ft19 BMC 17.15.100(B)(3)
  • 10 ft20 BMC 17.15.100(B)(5)(c)
Street side setback
  • 5 ft20 BMC 17.15.100(B)(5)(c)
  • 17 ft19 BMC 17.15.100(B)(2)
  • 5 ft20 BMC 17.15.100(B)(5)(c)
  • 17 ft21 BMC 17.15.100(B)(2)
  • 10 ft22 BMC 17.15.110(F)(2)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Rear setback20 ft BMC 17.15.100(B)(4)
  • 20 ft16 BMC 17.15.100(B)(4)
  • 10 ft3 BMC 17.15.110(F)(3)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Building separation10 ft BMC 17.15.100(B)(6)(a)
Maximum height35 ft BMC 17.15.100(D)
  • 35 ft16 BMC 17.15.100(D)
  • 25 ft3 BMC 17.15.110(B)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Maximum storiesNot set BMC 17.15.100
2 stories BMC 17.15.090(J)(7)
for Horizontally attached dwellings (3, 4+ units)7; Small multiunit buildings (3, 4+ units)7
Maximum lot coverage35% BMC 17.15.100(C)(1)
  • 35%16 BMC 17.15.100(C)(1)
  • 45%3 BMC 17.15.110(G)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Maximum impervious surface40% BMC 17.15.100(C)(2)
  • 40%16 BMC 17.15.100(C)(2)
  • 60%3 BMC 17.15.110(H)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Minimum parking
  • 1 space per unit23 BMC 17.85.060(A); Table 17.85.060
  • 2 spaces per unit24 BMC 17.85.060(A); Table 17.85.060
1 + sleeping units in the project spaces BMC 17.85.060(A); Table 17.85.060
for Small boarding houses (group living)
Maximum unit sizeNot set BMC 17.15.100
  • Not set16 BMC 17.15.100
  • 1,000 sq ft3 BMC 17.15.110(E)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Maximum building footprintNot set BMC 17.15.100
  • Not set16 BMC 17.15.100
  • 800 sq ft3 BMC 17.15.110(D)
for Detached dwellings (1 unit); Manufactured homes (1 unit)
Maximum units per buildingNot set BMC 17.15.100
4 units BMC 17.15.090(J)(8)
for Horizontally attached dwellings (3, 4+ units)7

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit BMC 17.15.090(K)(2)

Building

StandardValueExceptions
Front setback17 ft BMC 17.15.100(B)(1)
Side setback5 ft BMC 17.15.100(B)(3)
Rear setback20 ft BMC 17.15.100(B)(4)
5 ft BMC 17.15.090(K)(4)(b); 17.15.100(E)(4)(c)
for Detached dwellings (1 unit)2; Manufactured homes (1 unit)2; Duplex dwellings (2 units)6; Horizontally attached dwellings (3, 4+ units)9; Small multiunit buildings (3, 4+ units)9; Small boarding houses (group living)11
Maximum height35 ft BMC 17.15.100(D)
25 ft BMC 17.15.090(K)(3)(a); 17.15.100(E)(1)
for Detached dwellings (1 unit)2; Manufactured homes (1 unit)2; Duplex dwellings (2 units)6; Horizontally attached dwellings (3, 4+ units)9; Small multiunit buildings (3, 4+ units)9; Small boarding houses (group living)11
Maximum unit sizethe largest of 500, the smallest of 1,000, 0.3 × floor area of the main house sq ft BMC 17.15.090(K)(3)(b)
1,000 sq ft BMC 17.15.090(K)(3)(a)
for Detached dwellings (1 unit)2; Manufactured homes (1 unit)2; Duplex dwellings (2 units)6; Horizontally attached dwellings (3, 4+ units)9; Small multiunit buildings (3, 4+ units)9; Small boarding houses (group living)11
Attached to the main houseRequired BMC 17.15.090(K)(1)
Not required BMC 17.15.090(K)(1)
for Detached dwellings (1 unit)2; Manufactured homes (1 unit)2; Duplex dwellings (2 units)6; Horizontally attached dwellings (3, 4+ units)9; Small multiunit buildings (3, 4+ units)9; Small boarding houses (group living)11

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 16.10.050(A) A up to 9 BMC 16.01.060 —
Minimum lot size
6,000 sq ft BMC 17.15.100(A)(1)(b)
Minimum lot width
30 ft BMC 17.15.100(A)(2)
Minimum lot depth
80 ft BMC 17.15.100(A)(3)
Subdivision BMC 16.10.050(B); 16.10.080(B) H 10 or more BMC 16.01.060 —
Minimum lot size
6,000 sq ft BMC 17.15.100(A)(1)(b)
Minimum lot width
30 ft BMC 17.15.100(A)(2)
Minimum lot depth
80 ft BMC 17.15.100(A)(3)
Residential small lot development BMC 17.15.110; 16.10.050(A)Only for: Detached dwellings, Manufactured homes A up to 9 BMC 16.01.060 —
Minimum lot size
3,000 sq ft BMC 17.15.110(A)
Minimum lot width
30 ft BMC 17.15.100(A)(2)
Minimum lot depth
80 ft BMC 17.15.100(A)(3)
Maximum units per lot
1 unit BMC 17.15.110(J)
Residential small lot development BMC 17.15.110; 16.10.050(B); 16.10.080(B)Only for: Detached dwellings, Manufactured homes H 10 or more BMC 16.01.060 —
Minimum lot size
3,000 sq ft BMC 17.15.110(A)
Minimum lot width
30 ft BMC 17.15.100(A)(2)
Minimum lot depth
80 ft BMC 17.15.100(A)(3)
Maximum units per lot
1 unit BMC 17.15.110(J)
Cluster developments BMC 17.15.105; 16.10.050(A) A up to 9 BMC 16.01.060 11 units per acre BMC 17.15.105(B)(2)
Minimum lot size
alternative standards for lot width, lot depth, lot area, building and impervious surface coverage, and property line setbacks may be employed BMC 17.15.105
Cluster developments BMC 17.15.105; 16.10.050(B); 16.10.080(B) H 10 or more BMC 16.01.060 11 units per acre BMC 17.15.105(B)(2)
Minimum lot size
alternative standards for lot width, lot depth, lot area, building and impervious surface coverage, and property line setbacks may be employed BMC 17.15.105
Testamentary division BMC 16.70.060(A) A
Minimum lots
Not set BMC 16.70
—
Minimum lot size
6,000 sq ft BMC 17.15.100(A)(1)(b); BMC 16.70.080(A)(1)
Minimum lot width
30 ft BMC 17.15.100(A)(2)
Minimum lot depth
80 ft BMC 17.15.100(A)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • The ADU is located in a detached accessory building, not within the primary dwelling
    • Lot is created through the residential small lot development process
  2. All of these are true:
    • The ADU is located in a detached accessory building, not within the primary dwelling
    None of these is true:
    • Lot is created through the residential small lot development process
  3. Lot is created through the residential small lot development process
  4. None of these is true:
    • Lot shares a common side property line with another lot containing a duplex
  5. None of these is true:
    • Lot shares a common side property line with another lot containing a duplex
    • The ADU is located in a detached accessory building, not within the primary dwelling
  6. All of these are true:
    • The ADU is located in a detached accessory building, not within the primary dwelling
    None of these is true:
    • Lot shares a common side property line with another lot containing a duplex
  7. Lot is within 1,320 feet (travel distance) of a school, park, bus route, or commercially zoned parcel
  8. All of these are true:
    • Lot is within 1,320 feet (travel distance) of a school, park, bus route, or commercially zoned parcel
    None of these is true:
    • The ADU is located in a detached accessory building, not within the primary dwelling
  9. All of these are true:
    • Lot is within 1,320 feet (travel distance) of a school, park, bus route, or commercially zoned parcel
    • The ADU is located in a detached accessory building, not within the primary dwelling
  10. None of these is true:
    • The ADU is located in a detached accessory building, not within the primary dwelling
  11. The ADU is located in a detached accessory building, not within the primary dwelling
  12. The lot is being created or changed by a land division or boundary line adjustment
  13. None of these is true:
    • The lot is being created or changed by a land division or boundary line adjustment
  14. All of these are true:
    • The lot is being created or changed by a land division or boundary line adjustment
    None of these is true:
    • Lot is created through the residential small lot development process
  15. All of these are true:
    • The lot is being created or changed by a land division or boundary line adjustment
    • Lot is created through the residential small lot development process
  16. None of these is true:
    • Lot is created through the residential small lot development process
  17. All of these are true:
    • Lot is created through the residential small lot development process
    None of these is true:
    • Lot has alley access or curb cuts are prohibited by plat notes
  18. All of these are true:
    • Lot is created through the residential small lot development process
    • Lot has alley access or curb cuts are prohibited by plat notes
  19. None of these is true:
    • Lot adjoins streets on more than two sides
  20. Lot adjoins streets on more than two sides
  21. None of these is true:
    • Lot adjoins streets on more than two sides
    • Lot is created through the residential small lot development process
  22. All of these are true:
    • Lot is created through the residential small lot development process
    None of these is true:
    • Lot adjoins streets on more than two sides
  23. Bedrooms in one unit is at most 2