Sign in

PFT-1 · PFT-1 Public Facilities and Transportation Zone

Burlington, WA · BMC 17.68 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Public housing
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Employee or student housing
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Small nursing homes————
Home✓1 ADU—
Large nursing homes————
Home✓3 ADU—
Emergency housing————
Home✓1 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit BMC 17.68.090(A)(1)
Minimum lot widthNo limit BMC 17.68.090(A)(2)
Minimum lot depthNo limit BMC 17.68.090(A)(3)
Maximum bedsNot set BMC 17.68.090
8 beds BMC 17.01.050
for Small nursing homes (group living)1

3. Building standards

StandardValueExceptions
Front setback0 ft BMC 17.68.090(C)(1)
Maximum front setback10 ft BMC 17.68.090(D)(1)-(2)
Side setback0 ft BMC 17.68.090(C)(2)
Street side setback0 ft BMC 17.68.090(C)(3)
Rear setback0 ft BMC 17.68.090(C)(4)
Maximum height
  • 45 ft4 BMC 17.68.090(E)
  • 60 ft5 BMC 17.68.090(E); 17.68.090(E)(2)
  • Buildings may exceed 45 feet if one foot of setback is provided from each property line for each foot the building exceeds 45 feet6 BMC 17.68.090(E)(1)
Maximum lot coverageNo limit BMC 17.68.090(B)(1)
Maximum impervious surface80% BMC 17.68.090(B)(2)
Minimum parking
  • 1 space per unit7 BMC 17.85.060(A); Table 17.85.060
  • 2 spaces per unit8 BMC 17.85.060(A); Table 17.85.060
(beds in the project ÷ 6) + employees on the largest shift spaces BMC 17.85.060(A); Table 17.85.060
for Small nursing homes (group living)1; Large nursing homes (group living)3
For uses not specifically identified in this chapter, parking shall be provided as specified for the use which, in the opinion of the director, is most similar to the use under consideration. BMC 17.85.060(A)
for Emergency housing (group living)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 16.10.050(A) A up to 9 BMC 16.01.060 —
Minimum lot size
No limit BMC 17.68.090(A)(1)
Subdivision BMC 16.10.050(B); 16.10.080(B) H 10 or more BMC 16.01.060 —
Minimum lot size
No limit BMC 17.68.090(A)(1)
Testamentary division BMC 16.70.060(A) A
Minimum lots
Not set BMC 16.70
—
Minimum lot size
No limit BMC 17.68.090(A)(1)
Binding site plan BMC 16.30.060(A) A 2 or more BMC 16.30.020(A) —
Minimum lot size
No limit BMC 17.68.090(A)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The project is listed in, and consistent with, the city capital improvement plan or the public facilities element of the comprehensive plan
  2. The housing is incidental and subordinate to a legally established primary use on the site
  3. All of these are true:
    • Beds in the project is more than 8
    • The project is listed in, and consistent with, the city capital improvement plan or the public facilities element of the comprehensive plan
  4. None of these is true:
    • The building exceeds the base height by providing one foot of setback from each property line for each foot over 45 feet
    • Parking is located under the building
  5. All of these are true:
    • Parking is located under the building
    None of these is true:
    • The building exceeds the base height by providing one foot of setback from each property line for each foot over 45 feet
  6. The building exceeds the base height by providing one foot of setback from each property line for each foot over 45 feet
  7. Bedrooms in one unit is at most 2
  8. Bedrooms in one unit is at least 3