Sign in

MUC-1 · MUC-1 Mixed Use Commercial Zone

Burlington, WA · BMC 17.45 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwellings located in a mixed use building
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Employee or student housing
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
Home✓2 ADU—
—
Duplex dwellings—
HomeH3 ADU—
———
Horizontally attached dwellings——
Home✓1 ADU—
Home✓1 ADU—
—
Small multiunit buildings——
Home✓1 ADU—
Home✓1 ADU—
—
Medium multiunit buildings———
Home✓1 ADU—
—
Large multiunit buildings———
Home✓1 ADU—
—
Small nursing homes————
Home✓ ADU—
Large nursing homes————
Home✓4 ADU—
Emergency housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set BMC 17.45.090
4 units BMC 17.01.050
for Small multiunit buildings (4+ units)1
8 units BMC 17.01.050
for Medium multiunit buildings (4+ units)1
Minimum unitsNot set BMC 17.45.090
5 units BMC 17.01.050
for Medium multiunit buildings (4+ units)1
9 units BMC 17.01.050
for Large multiunit buildings (4+ units)1
Minimum lot sizeNo limit BMC 17.45.090(A)(1)
Minimum lot widthNo limit BMC 17.45.090(A)(2)
Minimum lot depthNo limit BMC 17.45.090(A)(3)
Maximum bedsNot set BMC 17.45.090
8 beds BMC 17.01.050
for Small nursing homes (group living)

3. Building standards

StandardValueExceptions
Front setback0 ft BMC 17.45.090(D)(1)
Maximum front setback
  • 10 ft5 BMC 17.45.090(E)(2); 17.45.090(F)
  • 0 ft6 BMC 17.45.090(E)(1)
Side setback0 ft BMC 17.45.090(D)(2)
Street side setback0 ft BMC 17.45.090(D)(3)
Rear setback0 ft BMC 17.45.090(D)(4)
Maximum height45 ft BMC 17.45.090(G)
Maximum impervious surface
  • 80%7 BMC 17.45.090(C)(2)
  • No limit8 BMC 17.45.090(C)(1)
Minimum parking
  • 1 space per unit9 BMC 17.85.060(A); Table 17.85.060
  • 2 spaces per unit10 BMC 17.85.060(A); Table 17.85.060
  • 1 space per unit11 BMC 17.85.060(A); Table 17.85.060
  • 1.5 spaces per unit12 BMC 17.85.060(A); Table 17.85.060
  • 2 spaces per unit10 BMC 17.85.060(A); Table 17.85.060
for Large multiunit buildings (4+ units)1
(beds in the project ÷ 6) + employees on the largest shift spaces BMC 17.85.060(A); Table 17.85.060
for Small nursing homes (group living); Large nursing homes (group living)4
For uses not specifically identified in this chapter, parking shall be provided as specified for the use which, in the opinion of the director, is most similar to the use under consideration. BMC 17.85.060(A)
for Emergency housing (group living)
Maximum building footprint6,000 sq ft BMC 17.45.090(B)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 16.10.050(A) A up to 9 BMC 16.01.060 —
Minimum lot size
No limit BMC 17.45.090(A)(1)
Subdivision BMC 16.10.050(B); 16.10.080(B) H 10 or more BMC 16.01.060 —
Minimum lot size
No limit BMC 17.45.090(A)(1)
Testamentary division BMC 16.70.060(A) A
Minimum lots
Not set BMC 16.70
—
Minimum lot size
No limit BMC 17.45.090(A)(1)
Binding site plan BMC 16.30.060(A) A 2 or more BMC 16.30.020(A) —
Minimum lot size
No limit BMC 17.45.090(A)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • None of these is true:
      • The building or site has frontage on an arterial street
    • At least 50 percent of the ground floor street frontage is devoted to a permitted nonresidential use
  2. All of these are true:
    • The housing is incidental and subordinate to a legally established primary use on the site
    • Any of these is true:
      • None of these is true:
        • The building or site has frontage on an arterial street
      • At least 50 percent of the ground floor street frontage is devoted to a permitted nonresidential use
  3. All of these are true:
    • Any of these is true:
      • The lot is not large enough to accommodate a more intensive residential use
      • The duplex is part of a larger development with a gross site density of at least 25 dwelling units per acre
    • Any of these is true:
      • None of these is true:
        • The building or site has frontage on an arterial street
      • At least 50 percent of the ground floor street frontage is devoted to a permitted nonresidential use
    None of these is true:
    • Lot has frontage on Fairhaven Avenue
  4. Beds in the project is more than 8
  5. None of these is true:
    • Lot has frontage on Fairhaven Avenue
  6. Lot has frontage on Fairhaven Avenue
  7. None of these is true:
    • Lot is Downtown
  8. Lot is Downtown
  9. Bedrooms in one unit is at most 2
  10. Bedrooms in one unit is at least 3
  11. Bedrooms in one unit is less than 1
  12. All of these are true:
    • Bedrooms in one unit is at least 1
    • Bedrooms in one unit is at most 2