RS 12,500 · Single-family residential – RS 12,500
Brier, WA · BMC 17.29 · Official code
By right: 1 unit, 2 units, 3 units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling of a permanent character placed in a permanent location | — | — | — | — | |
| Duplex | — | Home✓ ADU— | — | — | — |
| Cottage housing | — | Home✓ ADU— | Home✓ ADU— | — | — |
| Triplex | — | — | Home✓ ADU— | — | — |
| Townhouses | — | — | Home✓ ADU— | — | — |
| Multiple-family dwelling | — | — | Home✓ ADU— | — | — |
| Adult family home | — | — | — | — | |
| Group home | — | — | — | — | |
| Foster home | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Secure community transition facilities | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 3 units, ADUs included BMC 17.29.020(D)(1) | |
| Minimum lot size | ||
| Minimum lot width | ||
| Minimum frontage | 45 ft BMC 17.29.010(B) | |
| Maximum residents | 6 persons BMC 17.04.040 | (2 × bedrooms in the whole project) + 1 persons BMC 17.24.010(C)(6)(c)
for Permanent supportive housing (group living); Transitional housing (group living) 3 persons BMC 17.24.010(C)(4)(e)
for Secure community transition facilities (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 7 ft BMC 17.29.010(C)(2) | |
| Total side setbacks | 20 ft BMC 17.29.010(C)(2) | |
| Street side setback | ||
| Rear setback | 25 ft BMC 17.29.010(C)(3) | |
| Maximum height | 30 ft BMC 17.29.010(E) | |
| Maximum lot coverage | 45% BMC 17.29.010(D) | |
| Maximum impervious surface | 45% BMC 17.29.010(D); 17.04.040 | |
| Minimum parking | 2 spaces per unit BMC 17.29.010(F); 17.48.040(A)(1) | All non-single-family residential uses shall provide parking based on anticipated parking demand. For sites with over two thousand square feet of parking area or five thousand square feet of total impervious surface, the study shall be completed by a professional engineer or equally qualified individual with expertise in parking analyses. BMC 17.29.010(F); 17.48.045(A)(1); 17.48.045(B)(1)
Provides adequate on-site parking to accommodate the proposed use and all activities carried on in conjunction therewith BMC 17.24.010(C)(4)(b)
for Secure community transition facilities (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units BMC 17.29.030(D) | |
| Minimum lot size | 12,500 sq ft BMC 17.29.030(A); 17.29.010(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 35 ft BMC 17.29.030(B); 17.29.010(C)(1) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 30 ft BMC 17.29.030(B); 17.29.010(E) | |
| Minimum parking | 1 space per unit BMC 17.29.030(F); 17.48.040(A)(1) | |
| Maximum unit size | 1,000 sq ft BMC 17.29.030(E) | |
| Attached to the main house | Not required BMC 17.29.030(C) | |
| Owner lives on site | Not required BMC 17.29.030(K) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 16.32.050(M); 16.04.020(A) | A | up to 4 BMC 16.04.030 | — | Minimum lot size 12,500 sq ft BMC 16.16.130(D); 17.29.010(A) Minimum lot width 80 ft BMC 16.16.130(C); 17.29.010(B) Minimum lot depth 100 ft BMC 16.16.040(I) Minimum frontage 45 ft BMC 16.16.130(A); 17.29.010(B) Maximum units per lot 3 units BMC 17.29.020(D)(1) |
| Subdivision BMC 16.24.010; 16.24.030 | H | 5 or more BMC 16.04.030 | — | Minimum lot size 12,500 sq ft BMC 16.16.130(D); 17.29.010(A) Minimum lot width 80 ft BMC 16.16.130(C); 17.29.010(B) Minimum lot depth 100 ft BMC 16.16.040(I) Minimum frontage 45 ft BMC 16.16.130(A); 17.29.010(B) Maximum units per lot 3 units BMC 17.29.020(D)(1) |
| Unit lot short subdivision BMC 16.34.020; 16.34.030(A); 17.29.020(H)(2)(a)Only for: Single-family dwelling of a permanent character placed in a permanent location, Duplex, Townhouses | A | 2 to 4 BMC 17.04.040; BMC 16.34.030(A) | Maximum units 3 units BMC 17.29.020(D)(1); 17.29.020(H)(2)(c); 16.34.060(A) |
Minimum lot size Unit lot area and width per unit for purposes of unit lot subdivision may be as small as the coverage of the individual dwelling unit BMC 16.34.060(E) Minimum lot width Unit lot area and width per unit for purposes of unit lot subdivision may be as small as the coverage of the individual dwelling unit BMC 16.34.060(E) Minimum lot depth Not set BMC 16.34.060 Minimum frontage Not set BMC 16.34.060 Maximum units per lot Not set BMC 16.34.060 |
| Unit lot subdivision BMC 16.34.020; 16.34.030(B); 17.29.020(H)(2)(a)Only for: Single-family dwelling of a permanent character placed in a permanent location, Duplex, Townhouses | H | 5 or more BMC 16.34.030(B) | Maximum units 3 units BMC 17.29.020(D)(1); 17.29.020(H)(2)(c); 16.34.060(A) |
Minimum lot size Unit lot area and width per unit for purposes of unit lot subdivision may be as small as the coverage of the individual dwelling unit BMC 16.34.060(E) Minimum lot width Unit lot area and width per unit for purposes of unit lot subdivision may be as small as the coverage of the individual dwelling unit BMC 16.34.060(E) Minimum lot depth Not set BMC 16.34.060 Minimum frontage Not set BMC 16.34.060 Maximum units per lot Not set BMC 16.34.060 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- Lot area is at least 12,500 sf
- Lot width is at least 80 ft
- All of these are true:
- The operator is certified by the state of Washington (adult family homes, Chapter 388-76 WAC; group homes, Chapter 110-145 WAC)
- The home is located in the dwelling unit occupied by the licensed operator
- All of these are true:
- The operator is certified by the state of Washington (adult family homes, Chapter 388-76 WAC; group homes, Chapter 110-145 WAC)
- The home is located in the dwelling unit occupied by the licensed operator
- Lot area is at least 12,500 sf
- Lot width is at least 80 ft
- The lot is a pre-existing legal lot that lawfully existed before this zoning code but does not meet the minimum lot size or width
- None of these is true:
- The lot is a pre-existing legal lot that lawfully existed before this zoning code but does not meet the minimum lot size or width
- The abutting street right-of-way is designated to be widened
- None of these is true:
- The abutting street right-of-way is designated to be widened
- All of these are true:
- The ADU is detached from the principal unit
- The lot line where the ADU is sited abuts a public alley
- Not all of these are true:
- The ADU is detached from the principal unit
- The lot line where the ADU is sited abuts a public alley
- All of these are true:
- The ADU is detached from the principal unit
- The lot line where the ADU is sited abuts a public alley
- None of these is true:
- The ADU is detached from the principal unit