Sign in

High_Density_Residential · High density residential (R-40)

Bremerton, WA · BMC 20.79 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-unit dwelling unit, detached
Home✓ ADU✓1
————
Single-unit dwelling unit, attached (zero (0) lot lines)
Home✓ ADU✓1
————
Manufactured home
Home✓2 ADU✓3
————
Duplex—
Home✓ ADU—
———
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Multi-unit structure dwelling——
Home✓ ADU—
Home✓ ADU—
—
Senior housing complex———
Home✓4 ADU—
—
Manufactured home park———
Home✓ ADU—
—
Foster home————
Home✓ ADU—
Group residential facilities - Class I————
Home✓ ADU—
Nursing/convalescent home————
HomeA ADU—
Co-living housing————
Home✓5 ADU—
Transitional housing————
HomeA ADU—
Permanent supportive housing————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNot set BMC 20.79.060(a); 20.79.060(d)-(e)
87,120 sq ft BMC 20.46.190(a)(1)
for Senior housing complex (4+ units)4
217,800 sq ft BMC 20.46.200(a)(2)
for Manufactured home park (4+ units)
Minimum frontage20 ft BMC 20.42.040
Minimum density15 units per acre BMC 20.79.060(d)
Not set BMC 20.79.020(b); 20.79.060(e)
for Foster home (group living); Group residential facilities - Class I (group living); Nursing/convalescent home (group living); Co-living housing (group living)5; Transitional housing (group living); Permanent supportive housing (group living)
Maximum density
  • 40 units per acre, a fraction of 0.5 or more rounds up, on the net lot area6 BMC 20.79.020(b); 20.79.060(e); 20.44.090
  • 60 units per acre, a fraction of 0.5 or more rounds up, on the net lot area7 BMC 20.79.020(b); 20.79.060(e); 20.58.100(a); 20.44.090
Not set BMC 20.79.020(b); 20.79.060(e)
for Foster home (group living); Group residential facilities - Class I (group living); Nursing/convalescent home (group living); Co-living housing (group living)5; Transitional housing (group living); Permanent supportive housing (group living)
Maximum residentsNot set BMC 20.42.040
a full-time resident provides temporary care and supervision on a full-time basis to not more than six (6) foster children, three (3) expectant mothers, or three (3) other adults requiring full-time care BMC 20.42.040
for Foster home (group living)
Maximum sleeping unitsNot set BMC 20.42.040
4 × ((40 × lot area minus critical areas and buffers) ÷ 43,560, rounded) sleeping units BMC 20.79.020(b); 20.79.060(e); 20.46.230(c); 20.44.090
for Co-living housing (group living)5

3. Building standards

StandardValueExceptions
Front setback15 ft BMC 20.79.060(a)(1)(i)
Side setback5 ft BMC 20.79.060(a)(1)(ii)
Street side setback15 ft BMC 20.44.010(b)(2); 20.79.060(a)(1)(i)
Rear setback15 ft BMC 20.79.060(a)(1)(iii)
Building separationNot set BMC 20.79.060; 20.79.060(a); 20.79.060(a)(1)
10 ft BMC 20.46.200(a)(7); 20.46.200(a)(7)(iii)
for Manufactured home park (4+ units)
Maximum height65 ft BMC 20.79.060(a)(2); 20.79.060(a)(2)(i)
35 ft BMC 20.46.210(b); 20.46.210(d); 20.42.040
for Duplex (2 units); Townhouse (3, 4+ units); Multi-unit structure dwelling (3 units)
  • 35 ft8 BMC 20.46.210(b); 20.46.210(d); 20.42.040
  • 65 ft9 BMC 20.79.060(a)(2); 20.79.060(a)(2)(i)
for Multi-unit structure dwelling (4+ units)
Maximum impervious surface75% BMC 20.79.060(a)(3); 20.42.040
Minimum parking0 spaces per unit BMC 20.79.080; 20.48.060(i)
Minimum open spaceNot set BMC 20.79.060; 20.79.060(a); 20.79.060(a)(1)
  • 15%10 BMC 20.79.060(f)
  • Not set11 BMC 20.79.060; 20.79.060(a); 20.79.060(a)(1)
for Townhouse (4+ units); Multi-unit structure dwelling (4+ units); Senior housing complex (4+ units)4
10% BMC 20.46.200(a)(10)
for Manufactured home park (4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units BMC 20.46.010(c)

Building

StandardValueExceptions
Front setback15 ft BMC 20.79.060(a)(1)(i); 20.46.010(a); 20.44.060(a)
Side setback
  • 5 ft12 BMC 20.79.060(a)(1)(ii); 20.46.010(a)
  • 3 ft13 BMC 20.46.010(a); 20.44.060(b)
Rear setback
  • 15 ft12 BMC 20.79.060(a)(1)(iii); 20.46.010(a)
  • 3 ft13 BMC 20.46.010(a); 20.44.060(b)
Maximum height65 ft BMC 20.79.060(a)(2); 20.79.060(a)(2)(i); 20.46.010(a)
Minimum parking0 spaces per unit BMC 20.46.010(g); 20.48.060(i)
Maximum unit sizethe largest of 1,000, 0.6 × floor area of the main house sq ft BMC 20.46.010(e)
Attached to the main houseNot required BMC 20.46.010(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 20.12.090(a)(1)(i) A up to 9 BMC 20.12.080(a); 20.12.040 —
Minimum lot size
Not set BMC 20.79.060; 20.79.060(a); 20.79.060(a)(1)
Minimum lot width
Not set BMC 20.79.060; 20.79.060(a)
Minimum frontage
20 ft BMC 20.42.040
Formal subdivision BMC 20.12.090(a)(2)(i) H 10 or more BMC 20.12.080(b); 20.12.040 —
Minimum lot size
Not set BMC 20.79.060; 20.79.060(a); 20.79.060(a)(1)
Minimum lot width
Not set BMC 20.79.060; 20.79.060(a)
Minimum frontage
20 ft BMC 20.42.040
Unit lot subdivision BMC 20.12.090(a)(4)(i) A up to 9 BMC 20.12.080(d) —
Minimum lot size
Not set BMC 20.12.090(a)(4)(i); 20.12.080(d)
Minimum lot width
Not set BMC 20.12.090(a)(4)(i); 20.12.080(d)
Residential cluster development BMC 20.58.060; 20.58.060(b); 20.58.060(c); 20.58.060(c)(1); 20.58.060(d)(6); 20.58.060(e); 20.58.060(e)(1)Only for: Single-unit dwelling unit, detached, Single-unit dwelling unit, attached (zero (0) lot lines), Townhouse A —
  • 40 units per acre, a fraction of 0.5 or more rounds up6 BMC 20.79.020(b); 20.79.060(e); 20.44.090; 20.58.060(d)(1)
  • 60 units per acre, a fraction of 0.5 or more rounds up7 BMC 20.79.020(b); 20.79.060(e); 20.58.100(a); 20.44.090; 20.58.060(d)(1)
Minimum density
15 units per acre BMC 20.79.060(d)
Minimum lot size
Not set BMC 20.58.060(d)
Minimum lot width
Deviations are permitted. BMC 20.58.060(d)(3)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The ADU is served by City water and sewer or an approved septic system
  2. The manufactured home is a new manufactured home as defined in RCW 35.63.160(2)
  3. All of these are true:
    • The manufactured home is a new manufactured home as defined in RCW 35.63.160(2)
    • The ADU is served by City water and sewer or an approved septic system
  4. The complex provides access to alternative transportation such as public transit or on-site shuttle services to reach daily goods and services
  5. Lot area minus critical areas and buffers is at least 5,989.5 sf
  6. Not all of these are true:
    • The applicant is a religious organization as defined by RCW 26.04.007 or the Bremerton Housing Authority
    • All units within the development are affordable, and occupied by households whose income does not exceed the low-income household definition of RCW 84.14.010
    • The property owner agrees to a binding obligation, recorded as a notice to title, to use the development exclusively for affordable housing for at least 50 years
    • The project is approved for the affordable housing bonus through an administrative Type II conditional use permit
  7. All of these are true:
    • The applicant is a religious organization as defined by RCW 26.04.007 or the Bremerton Housing Authority
    • All units within the development are affordable, and occupied by households whose income does not exceed the low-income household definition of RCW 84.14.010
    • The property owner agrees to a binding obligation, recorded as a notice to title, to use the development exclusively for affordable housing for at least 50 years
    • The project is approved for the affordable housing bonus through an administrative Type II conditional use permit
  8. Main dwelling units on the lot is at most 6
  9. Main dwelling units on the lot is more than 6
  10. Main dwelling units on the lot is at least 25
  11. Main dwelling units on the lot is less than 25
  12. None of these is true: