District_Center_Core · District center core (DCC)
Bremerton, WA · BMC 20.70 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-unit dwelling unit, detached | — | — | — | — | |
| Single-unit dwelling unit, attached (zero (0) lot lines) | — | — | — | — | |
| Duplex | — | — | — | — | |
| Cottage housing development | — | — | |||
| Townhouse | — | — | — | ||
| Multi-unit structure dwelling | — | — | — | ||
| Senior housing complex | — | — | — | — | |
| Manufactured home park | — | — | — | — | |
| Foster home | — | — | — | — | |
| Group residential home | — | — | — | — | |
| Group residential facilities - Class I | — | — | — | — | |
| Nursing/convalescent home | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | |
| Indoor emergency shelter | — | — | — | — | |
| Indoor emergency housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set BMC 20.70.060 | 87,120 sq ft BMC 20.46.190(a)(1)
for Senior housing complex (4+ units)3 217,800 sq ft BMC 20.46.200(a)(2)
for Manufactured home park (4+ units)1 |
| Minimum frontage | 20 ft BMC 20.42.040 | |
| Minimum density | 30 units per acre BMC 20.70.060(d) | Not set BMC 20.70.060(d)
for Foster home (group living)1; Group residential home (group living)1; Group residential facilities - Class I (group living)1; Nursing/convalescent home (group living)1; Co-living housing (group living)1; Transitional housing (group living)1; Permanent supportive housing (group living)1; Indoor emergency shelter (group living)1; Indoor emergency housing (group living)1 |
| Maximum density | No limit BMC 20.70.060(d) | Not set BMC 20.70.060(d)
for Foster home (group living)1; Group residential home (group living)1; Group residential facilities - Class I (group living)1; Nursing/convalescent home (group living)1; Co-living housing (group living)1; Transitional housing (group living)1; Permanent supportive housing (group living)1; Indoor emergency shelter (group living)1; Indoor emergency housing (group living)1 |
| Maximum residents | Not set BMC 20.42.040 | a full-time resident provides temporary care and supervision on a full-time basis to not more than six (6) foster children, three (3) expectant mothers, or three (3) other adults requiring full-time care BMC 20.42.040
for Foster home (group living)1 6 persons BMC 20.42.040
for Group residential home (group living)1 |
| Maximum sleeping units | Not set BMC 20.42.040 | No limit BMC 20.70.060(d); 20.46.230(c)
for Co-living housing (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum front setback | 10 ft BMC 20.70.060(a) | |
| Side setback | ||
| Rear setback | ||
| Building separation | Not set BMC 20.70.060 | 10 ft BMC 20.46.200(a)(7); 20.46.200(a)(7)(iii)
for Manufactured home park (4+ units)1 |
| Maximum height | 80 ft BMC 20.70.060(g) | |
| Maximum stories | ||
| Maximum lot coverage | ||
| Maximum impervious surface | ||
| Minimum parking | 0 spaces per unit BMC 20.70.080; 20.48.060(i) | |
| Maximum unit size | Not set BMC 20.70.060 | 1,200 sq ft BMC 20.42.040
for Cottage housing development (2, 3, 4+ units)1 |
| Minimum open space | Not set BMC 20.70.060 | (40,000 × main dwelling units on the lot) ÷ lot area% BMC 20.46.170(a)(2); 20.46.170(a)(2)(i)
for Cottage housing development (2, 3, 4+ units)1 10% BMC 20.46.200(a)(10)
for Manufactured home park (4+ units)1 |
| Maximum units per building | Not set BMC 20.70.060 | 1 unit BMC 20.42.040
for Cottage housing development (2, 3, 4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units BMC 20.46.010(c) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | 0 ft BMC 20.70.060(b); 20.46.010(a) | |
| Rear setback | 0 ft BMC 20.70.060(c); 20.46.010(a) | |
| Maximum height | 80 ft BMC 20.70.060(g); 20.46.010(a) | |
| Maximum stories | ||
| Minimum parking | 0 spaces per unit BMC 20.46.010(g); 20.48.060(i) | |
| Maximum unit size | the largest of 1,000, 0.6 × floor area of the main house sq ft BMC 20.46.010(e) | |
| Attached to the main house | Not required BMC 20.46.010(b) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 20.12.090(a)(1)(i) | A | up to 9 BMC 20.12.080(a); 20.12.040 | — | Minimum lot size Not set BMC 20.70.060 Minimum lot width Not set BMC 20.70.060 Minimum frontage 20 ft BMC 20.42.040 |
| Formal subdivision BMC 20.12.090(a)(2)(i) | H | 10 or more BMC 20.12.080(b); 20.12.040 | — | Minimum lot size Not set BMC 20.70.060 Minimum lot width Not set BMC 20.70.060 Minimum frontage 20 ft BMC 20.42.040 |
| Unit lot subdivision BMC 20.12.090(a)(4)(i) | A | up to 9 BMC 20.12.080(d) | — | Minimum lot size Not set BMC 20.12.090(a)(4)(i); 20.12.080(d) Minimum lot width Not set BMC 20.12.090(a)(4)(i); 20.12.080(d) |
| Binding site plan BMC 20.12.090(a)(3)(i) | A10 | Maximum lots Not set BMC 20.12.080(c); 20.12.040 |
— | Minimum lot size Not set BMC 20.70.060 Minimum lot width Not set BMC 20.70.060 Minimum frontage 20 ft BMC 20.42.040 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Any of these is true:
- None of these is true:
- The structure that includes residential uses is located adjacent to, oriented towards, or viewable from a public right-of-way (not a private street)
- The structure provides retail/commercial uses along at least 50 percent of the ground-floor building facade
- The project complies with BMC 20.70.070(a)(6) (ground floor built for pedestrian-oriented uses or adaptable to them)
- None of these is true:
- All of these are true:
- Any of these is true:
- None of these is true:
- The structure that includes residential uses is located adjacent to, oriented towards, or viewable from a public right-of-way (not a private street)
- The structure provides retail/commercial uses along at least 50 percent of the ground-floor building facade
- The project complies with BMC 20.70.070(a)(6) (ground floor built for pedestrian-oriented uses or adaptable to them)
- None of these is true:
- The ADU is served by City water and sewer or an approved septic system
- Any of these is true:
- All of these are true:
- The complex provides access to alternative transportation such as public transit or on-site shuttle services to reach daily goods and services
- Any of these is true:
- None of these is true:
- The structure that includes residential uses is located adjacent to, oriented towards, or viewable from a public right-of-way (not a private street)
- The structure provides retail/commercial uses along at least 50 percent of the ground-floor building facade
- The project complies with BMC 20.70.070(a)(6) (ground floor built for pedestrian-oriented uses or adaptable to them)
- None of these is true:
- None of these is true:
- This lot line adjoins the low density (R-10) or medium density (R-18) residential zone
- This lot line adjoins the low density (R-10) or medium density (R-18) residential zone
- The structure (or part of it) is within 50 linear feet of parcels zoned low density residential
- None of these is true:
- The structure (or part of it) is within 50 linear feet of parcels zoned low density residential
- None of these is true:
- The project uses the DCC coverage bonus menu (mixed use, three or more stories, pedestrian plaza, through-block corridor, structured parking)
- The project uses the DCC coverage bonus menu (mixed use, three or more stories, pedestrian plaza, through-block corridor, structured parking)
- The land division is for a commercial and/or industrial development