City_Utility_Land · City utility lands (CUL)
Bremerton, WA · BMC 20.96 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-unit dwelling unit, detached | — | — | — | — | |
| Single-unit dwelling unit, attached (zero (0) lot lines) | — | — | — | — | |
| Townhouse | — | — | — | ||
| Senior housing complex | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set BMC 20.96.060; 20.96.040(a)(6) | 87,120 sq ft BMC 20.46.190(a)(1)
for Senior housing complex (4+ units)3 |
| Minimum lot width | 30 ft BMC 20.96.040(a)(6); 20.60.060(a)(3) | |
| Minimum frontage | 20 ft BMC 20.42.040 | |
| Maximum density | for Senior housing complex (4+ units)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum height | 35 ft BMC 20.96.040(a)(6); 20.60.060(a)(2) | |
| Maximum impervious surface | 60% BMC 20.96.040(a)(6); 20.60.060(a)(4); 20.42.040 | |
| Minimum parking | 0 spaces per unit BMC 20.96.080; 20.48.060(i) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units BMC 20.46.010(c) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft BMC 20.96.040(a)(6); 20.60.060(a)(2); 20.46.010(a) | |
| Minimum parking | 0 spaces per unit BMC 20.46.010(g); 20.48.060(i) | |
| Maximum unit size | the largest of 1,000, 0.6 × floor area of the main house sq ft BMC 20.46.010(e) | |
| Attached to the main house | Not required BMC 20.46.010(b) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 20.12.090(a)(1)(i) | A | up to 9 BMC 20.12.080(a); 20.12.040 | — | Minimum lot size Not set BMC 20.96.060; 20.96.040(a)(6) Minimum lot width 30 ft BMC 20.96.040(a)(6); 20.60.060(a)(3) Minimum frontage 20 ft BMC 20.42.040 |
| Formal subdivision BMC 20.12.090(a)(2)(i) | H | 10 or more BMC 20.12.080(b); 20.12.040 | — | Minimum lot size Not set BMC 20.96.060; 20.96.040(a)(6) Minimum lot width 30 ft BMC 20.96.040(a)(6); 20.60.060(a)(3) Minimum frontage 20 ft BMC 20.42.040 |
| Unit lot subdivision BMC 20.12.090(a)(4)(i) | A | up to 9 BMC 20.12.080(d) | — | Minimum lot size Not set BMC 20.12.090(a)(4)(i); 20.12.080(d) Minimum lot width Not set BMC 20.12.090(a)(4)(i); 20.12.080(d) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The location does not interfere with City public utility functions and activities
- The location is adjacent to an existing recreational or residential use
- All of these are true:
- The location does not interfere with City public utility functions and activities
- The location is adjacent to an existing recreational or residential use
- The ADU is served by City water and sewer or an approved septic system
- All of these are true:
- The complex provides access to alternative transportation such as public transit or on-site shuttle services to reach daily goods and services
- The location does not interfere with City public utility functions and activities
- The location is adjacent to an existing recreational or residential use
- Not all of these are true:
- The applicant is a religious organization as defined by RCW 26.04.007 or the Bremerton Housing Authority
- All units within the development are affordable, and occupied by households whose income does not exceed the low-income household definition of RCW 84.14.010
- The property owner agrees to a binding obligation, recorded as a notice to title, to use the development exclusively for affordable housing for at least 50 years
- The project is approved for the affordable housing bonus through an administrative Type II conditional use permit
- All of these are true:
- The applicant is a religious organization as defined by RCW 26.04.007 or the Bremerton Housing Authority
- All units within the development are affordable, and occupied by households whose income does not exceed the low-income household definition of RCW 84.14.010
- The property owner agrees to a binding obligation, recorded as a notice to title, to use the development exclusively for affordable housing for at least 50 years
- The project is approved for the affordable housing bonus through an administrative Type II conditional use permit
- None of these is true:
- The ADU is detached from the principal unit
- The ADU is detached from the principal unit