Sign in

RC-5 · RC-5 residential/conservation district

Bonney Lake, WA · BLMC 18.20 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family residences
Home✓ ADU✓1 ✓2
————
Mobile/manufactured homes
Home✓ ADU✓1 ✓2
————
Adult family home————
Home✓ ADU—
Group homes————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum density1 unit per 5 × 43,560 sq ft, a fraction over 0.5 rounds up BLMC 18.20.050(A)
Not set BLMC 18.20.050
for Adult family home (group living); Group homes (group living)
Maximum residents6 persons BLMC 18.04.010
Not set BLMC 18.20.050
for Group homes (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 55 ft3 BLMC 18.20.050(B)(1)
  • 30 ft4 BLMC 18.20.050(B)(2)
Side setback
  • 30 ft5 BLMC 18.20.050(C)(1)
  • 15 ft6 BLMC 18.20.050(C)(2)
Rear setback
  • 60 ft5 BLMC 18.20.050(D)(1)
  • 30 ft6 BLMC 18.20.050(D)(2)
Maximum height35 ft BLMC 18.20.050(E)
Minimum parking2 spaces per unit BLMC 18.22.100(A)
Where a use is not listed, in cases where only a broad use category is shown, or if there is a request for an alternative parking ratio submitted, the director shall utilize the current version of the Parking Generation Manual prepared by the Institute of Transportation Engineers. BLMC 18.31.010(G)
for Group homes (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit BLMC 18.22.090(C)(1)(a)-(b)
2 units BLMC 18.22.090(C)(1)(c)
for Single-family residences (1 unit)2; Mobile/manufactured homes (1 unit)2
Minimum lot size2,000 sq ft BLMC 18.22.090(C)(1)

Building

StandardValueExceptions
Front setback
  • 55 ft3 BLMC 18.22.090(C)(10); 18.20.050(B)(1)
  • 30 ft4 BLMC 18.22.090(C)(10); 18.20.050(B)(2)
Side setback
  • 30 ft5 BLMC 18.22.090(C)(10); 18.20.050(C)(1)
  • 15 ft6 BLMC 18.22.090(C)(10); 18.20.050(C)(2)
Rear setback
  • 60 ft5 BLMC 18.22.090(C)(10); 18.20.050(D)(1)
  • 30 ft6 BLMC 18.22.090(C)(10); 18.20.050(D)(2)
Maximum height
  • 24 ft7 BLMC 18.22.090(C)(10)(b)
  • 35 ft8 BLMC 18.22.090(C)(10); 18.20.050(E)
Minimum parking
  • 1 space per unit9 BLMC 18.22.090(C)(9)(a)
  • 1 space per unit10 BLMC 18.22.090(C)(9)(a)
  • 2 spaces per unit11 BLMC 18.22.090(C)(9)(a)
Maximum unit size
  • 1,200 sq ft7 BLMC 18.22.090(C)(4)(b)
  • 1,000 sq ft12 BLMC 18.22.090(C)(4)(a)
  • 0.4 × floor area of the main house sq ft13 BLMC 18.22.090(C)(4)(a)
  • 1,200 sq ft14 BLMC 18.22.090(C)(4)(a)
Attached to the main houseNot required BLMC 18.22.090(C)(1)(a)-(c)
Owner lives on siteRequired BLMC 18.22.090(B)(2)
Not set BLMC 18.22.090(B)
for Single-family residences (1 unit)2; Mobile/manufactured homes (1 unit)2

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BLMC 17.20.020 ✓ up to 9 BLMC 17.10.030(C)(4) 1 unit per 5 × 43,560 sq ft, a fraction over 0.5 rounds up BLMC 18.20.050(A)
Minimum lot width
Not set BLMC 17.50.020(A); 18.20.050
Subdivision BLMC 17.20.020 ✓ 10 or more BLMC 17.10.030(C)(5) 1 unit per 5 × 43,560 sq ft, a fraction over 0.5 rounds up BLMC 18.20.050(A)
Minimum lot width
Not set BLMC 17.50.020(A); 18.20.050

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The lot contains any undevelopable critical area, as defined in BLMC 16.20.030
    • The lot is fully or partially within a watershed serving a potable water reservoir listed as of July 1, 2025 as impaired or threatened under Section 303(d) of the Clean Water Act
  2. None of these is true:
    • The lot contains any undevelopable critical area, as defined in BLMC 16.20.030
    • The lot is fully or partially within a watershed serving a potable water reservoir listed as of July 1, 2025 as impaired or threatened under Section 303(d) of the Clean Water Act
  3. The front setback is measured from State Highway 410
  4. None of these is true:
    • The front setback is measured from State Highway 410
  5. Lot area is at least 22,000 sf
  6. Lot area is less than 22,000 sf
  7. The ADU is detached from the primary dwelling unit
  8. None of these is true:
    • The ADU is detached from the primary dwelling unit
  9. Lot area is at most 6,000 sf
  10. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at most 1
  11. All of these are true:
    • Lot area is more than 6,000 sf
    • Bedrooms in one ADU is at least 2
  12. All of these are true:
    • Floor area of the main house is at most 2,500
    None of these is true:
    • The ADU is detached from the primary dwelling unit
  13. All of these are true:
    • Floor area of the main house is more than 2,500
    • Floor area of the main house is at most 3,000
    None of these is true:
    • The ADU is detached from the primary dwelling unit
  14. All of these are true:
    • Floor area of the main house is more than 3,000
    None of these is true:
    • The ADU is detached from the primary dwelling unit