RM · Residential medium-density
Blaine, WA · BMC 17.30 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Residence | Home✓ ADU— | — | — | — | — |
| Manufactured home (designated) | — | — | — | — | |
| Duplex | — | Home✓ ADU— | — | — | — |
| Triplex | — | — | Home✓ ADU— | — | — |
| Fourplex | — | — | — | Home✓ ADU— | — |
| Fiveplex | — | — | — | Home✓ ADU— | — |
| Sixplex | — | — | — | Home✓ ADU— | — |
| Adult family care facility | — | — | — | — | HomeA ADU— |
| Elderly Housing | — | — | — | — | HomeH ADU— |
| Nursing or convalescent home | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units BMC 17.142.240 | 5 units BMC 17.30.020
for Fiveplex (4+ units) 6 units BMC 17.30.020
for Sixplex (4+ units) |
| Minimum lot size | 6,000 sq ft BMC 17.30.030 | 7,500 sq ft BMC 17.30.030
for Duplex (2 units) 11,250 sq ft BMC 17.30.030
for Triplex (3 units) 15,000 sq ft BMC 17.30.030
for Fourplex (4+ units) 18,500 sq ft BMC 17.30.030
for Fiveplex (4+ units) 22,000 sq ft BMC 17.30.030
for Sixplex (4+ units) |
| Minimum lot width | 50 ft BMC 17.30.030 | |
| Maximum residents | Not set BMC 17.30.030 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft BMC 17.30.030 | |
| Side setback | 8 ft BMC 17.30.030 | |
| Street side setback | 15 ft BMC 17.30.030 | |
| Rear setback | ||
| Maximum height | 35 ft BMC 17.30.030 | |
| Minimum parking | 2 spaces per unit BMC 17.30.030 | 2 + 2 spaces BMC 17.100.030(E)
for Adult family care facility (group living) Not read BMC 17.124.080
for Elderly Housing (group living); Nursing or convalescent home (group living) |
| Minimum open space | 30% BMC 17.30.030 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 17.58.040(A); Table 17.06.A | A | up to 9 BMC 17.58.020 | — | Minimum lot size 6,000 sq ft BMC 17.30.030 Minimum lot width 50 ft BMC 17.30.030 |
| Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A | A | 10 to 99 BMC 17.60.020; BMC Table 17.06.A | — | Minimum lot size 6,000 sq ft BMC 17.30.030 Minimum lot width 50 ft BMC 17.30.030 |
| Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A | H | 100 or more BMC Table 17.06.A | — | Minimum lot size 6,000 sq ft BMC 17.30.030 Minimum lot width 50 ft BMC 17.30.030 |
| Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A | H6 | — | Minimum parent area 130,680 sq ft BMC 17.68.020(A) |
Minimum lot size 4,000 sq ft BMC 17.68.120(C) Minimum lot width Lots within a residential PUD may vary from the depth, width and size requirements established in the code for the underlying zoning district, as determined to be suitable for the proposed PUD subject to the standards of this chapter. BMC 17.68.120(F) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
- The state licensing department determines the home and provider can serve up to six adults
- None of these is true:
- The state licensing department determines the home and provider can serve up to six adults
- The lot is a corner lot
- None of these is true:
- The lot is a corner lot
- Lot area is at least 130,680 sf
- None of these is true:
- The PUD uses the superior design density bonuses (up to 20% above base density)
- The PUD uses the superior design density bonuses (up to 20% above base density)