Sign in

PR · Planned residential

Blaine, WA · BMC 17.42 · Official code

By right: 1 unit · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-Family Residence
Home✓ ADUA1 A2 A3 A4 A5 H6
————
Manufactured home (designated)
Home✓7 ADUA8 A9 A10 A11 A12 H12 H13
————
Attached Single-Family Dwelling Units—
Home✓14 ADU—
Home✓14 ADU—
Home✓14 ADU—
—
Manufactured home park———
HomeA ADU—
—
Retirement homes————
HomeH ADU—
Boardinghouse or roominghouse————
HomeH ADU—
Nursing or convalescent home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size
  • Not set14 BMC 17.42.050
  • 217,800 sq ft15 BMC 17.42.050
Not set BMC 17.116.050
for Manufactured home park (4+ units)
Minimum lot width
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 75 ft17 BMC 17.42.060(D)
Not set BMC 17.116.050
for Manufactured home park (4+ units)
Maximum density
  • 4 units per acre14 BMC 17.42.050
  • 1 unit per 217,800 sq ft15 BMC 17.42.050
1.5 × 4 units per acre BMC 17.116.050(A)(1); 17.42.050
for Manufactured home park (4+ units)
Minimum development sizeNot set BMC 17.42
130,680 sq ft BMC 17.116.050(B)(1)
for Manufactured home park (4+ units)
Maximum residentsNot set BMC 17.42
5 persons BMC 17.142.080
for Boardinghouse or roominghouse (group living)

3. Building standards

StandardValueExceptions
Front setback
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 25 ft17 BMC 17.42.060(A)(1)
10 ft BMC 17.116.060(B)(3)
for Manufactured home park (4+ units)
Side setback
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 8 ft17 BMC 17.42.060(A)(3)
0 ft BMC 17.116.060(B)(4)
for Manufactured home park (4+ units)
Street side setback
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 0.75 × 25 ft17 BMC 17.130.020(B); 17.42.060(A)(1)
Not set BMC 17.116.060
for Manufactured home park (4+ units)
Rear setback
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 8 ft18 BMC 17.130.020(D); 17.42.060(A)(3)
  • 30 ft19 BMC 17.42.060(A)(2)
0 ft BMC 17.116.060(B)(4)
for Manufactured home park (4+ units)
Building separationNot set BMC 17.42
10 ft BMC 17.116.060(B)(1)
for Manufactured home park (4+ units)
Maximum height
  • 35 ft16 BMC 17.42.060(E)
  • 30 ft17 BMC 17.42.060(B)
30 ft BMC 17.116.060(C)(1); 17.42.060(B)
for Manufactured home park (4+ units)
Maximum stories
  • 3 stories16 BMC 17.42.060(E)
  • Not set17 BMC 17.42.060
Not set BMC 17.116.060
for Manufactured home park (4+ units)
Maximum lot coverageNot set BMC 17.42
50% BMC 17.116.060(A)
for Manufactured home park (4+ units)
Minimum parkingNot read BMC 17.42.070; 17.124.080
(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces BMC 17.116.050(E)(1)-(2)
for Manufactured home park (4+ units)
Maximum lot sizeNot set BMC 17.42
653,400 sq ft BMC 17.116.050(B)(2)
for Manufactured home park (4+ units)
Minimum open space
  • 20%16 BMC 17.42.060(E)
  • 40%17 BMC 17.42.060(C)
20% BMC 17.116.050(G)(1)
for Manufactured home park (4+ units)
Maximum units per buildingNot set BMC 17.42
4 units BMC 17.42.020(B)
for Attached Single-Family Dwelling Units (2, 3, 4+ units)14

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit BMC 17.102.020

Building

StandardValueExceptions
Front setbackDetached accessory dwelling units shall not be forward of the primary unit in relation to any public street. BMC 17.102.050(A)
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 25 ft17 BMC 17.42.060(A)(1)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Side setback4 ft BMC 17.102.050(A); 17.104.010
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 8 ft17 BMC 17.42.060(A)(3)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
for Single-Family Residence (1 unit)6; Manufactured home (designated) (1 unit)13
Rear setback8 ft BMC 17.102.050(A); 17.104.010
  • Those properties developed as a planned unit development shall have setbacks, open area, and lot width established and approved as part of the planned unit development process.16 BMC 17.42.060(E)
  • 8 ft18 BMC 17.130.020(D); 17.42.060(A)(3)
  • 30 ft19 BMC 17.42.060(A)(2)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Conversion of an existing accessory structure, noncompliant with the accessory structure setbacks, on an otherwise compliant lot may be conditionally permitted without a variance. Under no circumstance may the accessory structure encroach onto adjacent private or public property BMC 17.102.030(B)(1)
for Single-Family Residence (1 unit)6; Manufactured home (designated) (1 unit)13
Maximum height28 ft BMC 17.102.050(I)
  • 35 ft16 BMC 17.42.060(E)
  • 30 ft17 BMC 17.42.060(B)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Maximum stories
  • 3 stories16 BMC 17.42.060(E)
  • Not set17 BMC 17.42.060
Minimum parkingNot read BMC 17.102.050(E); 17.124.080
Maximum unit size1,000 sq ft BMC 17.102.030(B)(2)
Not read BMC 17.102.030(A)(1)
for Single-Family Residence (1 unit)1; Manufactured home (designated) (1 unit)8
the smallest of 0.5 × floor area of the main house, 600 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)2; Manufactured home (designated) (1 unit)9
the smallest of 0.5 × floor area of the main house, 800 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)3; Manufactured home (designated) (1 unit)10
the smallest of 0.5 × floor area of the main house, 1,000 sq ft BMC 17.102.030(A)(2)
for Single-Family Residence (1 unit)4; Manufactured home (designated) (1 unit)11
  • 0.5 × floor area of the main house sq ft20 BMC 17.102.030(A)(3)
  • the smallest of 0.4 × floor area of the main house, 1,000 sq ft21 BMC 17.102.030(A)(3)
  • the smallest of 0.3 × floor area of the main house, 1,200 sq ft22 BMC 17.102.030(A)(3)
  • the smallest of 0.2 × floor area of the main house, 1,500 sq ft23 BMC 17.102.030(A)(3)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Attached to the main houseNot required BMC 17.102.030(A)(1)-(2); 17.142.027
Required BMC 17.102.030(A)(3)
for Single-Family Residence (1 unit)5; Manufactured home (designated) (1 unit)12
Owner lives on siteRequired BMC 17.102.050(C); 17.102.070(C)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision BMC 17.58.040(A); Table 17.06.A A24 up to 9 BMC 17.58.020 —
Minimum lot size
  • Not set14 BMC 17.42.050
  • 217,800 sq ft15 BMC 17.42.050
Minimum lot width
75 ft BMC 17.42.060(D)
Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A A24 10 to 99 BMC 17.60.020; BMC Table 17.06.A
Minimum density
4 units per acre BMC 17.42.050(A)
Minimum lot size
  • Not set14 BMC 17.42.050
  • 217,800 sq ft15 BMC 17.42.050
Minimum lot width
75 ft BMC 17.42.060(D)
Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A H24 100 or more BMC Table 17.06.A
Minimum density
4 units per acre BMC 17.42.050(A)
Minimum lot size
  • Not set14 BMC 17.42.050
  • 217,800 sq ft15 BMC 17.42.050
Minimum lot width
75 ft BMC 17.42.060(D)
Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A H25 —
  • 4 units per acre26 BMC 17.68.120(B); 17.68.125
  • 4 × 1.2 units per acre27 BMC 17.68.125; 17.68.130
Minimum parent area
130,680 sq ft BMC 17.68.020(A)
Minimum lot size
4,000 sq ft BMC 17.68.120(C)
Minimum lot width
Lots within a residential PUD may vary from the depth, width and size requirements established in the code for the underlying zoning district, as determined to be suitable for the proposed PUD subject to the standards of this chapter. BMC 17.68.120(F)
Manufactured home subdivision BMC 17.42.020(G); 17.114.020; 17.114.030; Table 17.06.AOnly for: Manufactured home (designated) A 10 or more BMC 17.114.040(A) —
Minimum lot width
75 ft BMC 17.42.060(D)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The lot is served by public water and sewer
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  2. All of these are true:
    • The lot is served by public water and sewer
    • Lot area is at least 6,000 sf
    • Lot area is at most 8,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  3. All of these are true:
    • The lot is served by public water and sewer
    • Lot area is more than 8,000 sf
    • Lot area is at most 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  4. All of these are true:
    • The lot is served by public water and sewer
    • Lot area is more than 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  5. The lot is served by public water and sewer
  6. All of these are true:
    • The lot is served by public water and sewer
    • The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
  7. The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
  8. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  9. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
    • Lot area is at least 6,000 sf
    • Lot area is at most 8,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  10. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
    • Lot area is more than 8,000 sf
    • Lot area is at most 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  11. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
    • Lot area is more than 11,000 sf
    None of these is true:
    • The detached ADU substantially complies with the city ADU Templates 1 through 4
  12. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
  13. All of these are true:
    • The manufactured home is a new manufactured home (not previously titled to a retail purchaser)
    • The lot is served by public water and sewer
    • The ADU converts an existing accessory structure that does not meet the accessory structure setbacks, on an otherwise compliant lot
  14. Public sewer, water, storm water collection (quality) and retention (quantity) facilities serve the site
  15. None of these is true:
    • Public sewer, water, storm water collection (quality) and retention (quantity) facilities serve the site
  16. The property is developed as a planned unit development
  17. None of these is true:
    • The property is developed as a planned unit development
  18. All of these are true:
    • The lot is a corner lot
    None of these is true:
    • The property is developed as a planned unit development
  19. None of these is true:
    • The property is developed as a planned unit development
    • The lot is a corner lot
  20. Floor area of the main house is less than 2,000
  21. All of these are true:
    • Floor area of the main house is at least 2,000
    • Floor area of the main house is less than 3,000
  22. All of these are true:
    • Floor area of the main house is at least 3,000
    • Floor area of the main house is less than 5,000
  23. Floor area of the main house is at least 5,000
  24. Lot area is at most 217,800 sf
  25. Lot area is at least 130,680 sf
  26. None of these is true:
    • The PUD uses the superior design density bonuses (up to 20% above base density)
  27. The PUD uses the superior design density bonuses (up to 20% above base density)