HCa · Highway commercial – subzone A
Blaine, WA · BMC 17.24 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling units in conjunction with and accessory to the permitted use | — | ||||
| High-density residential development | HomeH ADU— | — | HomeH ADU— | HomeH ADU— | — |
| Nursing or convalescent home | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit BMC 17.24.050 | 6,000 sq ft BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Minimum lot width | 50 ft BMC 17.24.060 | |
| Maximum density | Not set BMC 17.24.060 | 24 units per acre BMC 17.24.040(A)(2); 17.28.020
for High-density residential development (3, 4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft BMC 17.24.060 | 20 ft BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Side setback | 10 ft BMC 17.24.060 | 8 ft BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Street side setback | 0.75 × 15 ft BMC 17.130.020(B); 17.24.060 | 15 ft BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Rear setback | 10 ft BMC 17.24.060 | |
| Maximum height | 35 ft BMC 17.24.060 | |
| Maximum impervious surface | 100% BMC 17.24.060; 17.142.335 | Not set BMC 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Minimum parking | Not read BMC 17.24.070; 17.124.080 | 2 spaces per unit BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
| Minimum open space | Not set BMC 17.24.060 | 30% BMC 17.24.040(A)(2); 17.28.030
for High-density residential development (1, 3, 4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision BMC 17.58.040(A); Table 17.06.A | A | up to 9 BMC 17.58.020 | — | Minimum lot size No limit BMC 17.24.050 Minimum lot width 50 ft BMC 17.24.060 |
| Preliminary plat BMC 17.60.120(A); 17.06.040(A)(1)(b); Table 17.06.A | A | 10 to 99 BMC 17.60.020; BMC Table 17.06.A | — | Minimum lot size No limit BMC 17.24.050 Minimum lot width 50 ft BMC 17.24.060 |
| Preliminary plat BMC 17.60.120(B); 17.60.130; Table 17.06.A | H | 100 or more BMC Table 17.06.A | — | Minimum lot size No limit BMC 17.24.050 Minimum lot width 50 ft BMC 17.24.060 |
| Binding site plan BMC 17.64.010; Table 17.06.A | A | Minimum lots Not set BMC 17.64 |
— | Minimum lot size No limit BMC 17.24.050 Minimum lot width 50 ft BMC 17.24.060 |
| Planned unit development (PUD) BMC 17.68.020(D); 17.02.050(B)(3)(a); Table 17.06.A | H4 | — | Residential uses in PUDs in PC, HCx, GW and MPR districts shall be as permitted by the review authority. BMC 17.68.030(B) Minimum parent area 217,800 sq ft BMC 17.68.020(A) |
Minimum lot size To permit greater flexibility and consequently more creative and imaginative design for the development of residential and business uses than is generally possible under conventional zoning regulations including alteration of bulk and scale requirements as may be included in the underlying zoning district; BMC 17.68.010(A); 17.68.090(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The dwelling units are built in conjunction with and accessory to a permitted use on the site
- The lot is a corner lot
- None of these is true:
- The lot is a corner lot
- Lot area is at least 217,800 sf