F-1 · Factoria Land Use District 1
Bellevue, WA · LUC 20.10.395(A); 20.25F1 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling Unit | — | ||||
| Rooming House | — | — | — | — | |
| Supportive Housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
No standards.
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Street side setback | ||
| Maximum height | ||
| Maximum impervious surface | 85% LUC 20.25F1.040 | |
| Maximum floor area ratio | ||
| Minimum parking | The Director of the Development Services Department shall establish the minimum number of parking spaces required and may establish the maximum number of parking spaces allowed as a component of the Master Development Plan approval that is required for all development in the F1 Land Use District. LUC 20.25F1.060(A) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units LUC 20.20.120(C)(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Minimum parking | The Director of the Development Services Department shall establish the minimum number of parking spaces required and may establish the maximum number of parking spaces allowed as a component of the Master Development Plan approval that is required for all development in the F1 Land Use District. LUC 20.25F1.060(A) | |
| Maximum unit size | 1,200 sq ft LUC 20.20.120(C)(3) | |
| Attached to the main house | Not required LUC 20.20.120(A) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, Short LUC 20.45B.020; 20.45B.080; 20.45B.130 | A | up to 9 LUC 20.50.046 | — | Minimum lot size Not set LUC 20.45A.050 |
| Subdivision LUC 20.45A.170; 20.45A.210 | H | 10 or more LUC 20.50.046 | — | Minimum lot size Not set LUC 20.45A.050 |
| Unit lot short subdivision LUC 20.45B.057(A)(1); 20.45B.130Only for: Dwelling Unit | A18 | up to 9 LUC 20.50.046 | — | Minimum lot size Development on individual unit lots within the unit lot short subdivision need not conform to the minimum lot area, minimum density, or dimensional requirements LUC 20.45B.057(B)(2) |
| Unit lot subdivision LUC 20.45A.065(A)(1); 20.45A.170Only for: Dwelling Unit | H18 | 10 or more LUC 20.50.046 | — | Minimum lot size Development on individual unit lots within the unit lot subdivision need not conform to the minimum lot area, minimum density, or dimensional requirements LUC 20.45A.065(B)(2) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is a unit lot created through a unit lot subdivision or unit lot short subdivision and developed in accordance with that approval
- The site contains a business subject to a Home Occupation Permit (Part 20.30N LUC)
- The lot allows at least six dwelling units by right, not only through an affordable housing density bonus
- All of these are true:
- The lot allows at least six dwelling units by right, not only through an affordable housing density bonus
- The lot is a unit lot created through a unit lot subdivision or unit lot short subdivision and developed in accordance with that approval
- The site contains a business subject to a Home Occupation Permit (Part 20.30N LUC)
- The supportive housing meets the requirements in LUC 20.20.845
- All of these are true:
- The supportive housing meets the requirements in LUC 20.20.845
- The lot is a unit lot created through a unit lot subdivision or unit lot short subdivision and developed in accordance with that approval
- The site contains a business subject to a Home Occupation Permit (Part 20.30N LUC)
- All of these are true:
- The F1 development area the site is in is da_ii
- The setback is along a Type A or Type C street designated under LUC 20.25F1.015
- Not all of these are true:
- The F1 development area the site is in is da_ii
- The setback is along a Type A or Type C street designated under LUC 20.25F1.015
- The F1 development area the site is in is one of da_i, da_iii, da_iv
- The F1 development area the site is in is da_ii
- The accessory dwelling unit is detached from the primary structure
- All of these are true:
- The F1 development area the site is in is da_ii
- The setback is along a Type A or Type C street designated under LUC 20.25F1.015
- The accessory dwelling unit is detached from the primary structure
- All of these are true:
- Not all of these are true:
- The F1 development area the site is in is da_ii
- The setback is along a Type A or Type C street designated under LUC 20.25F1.015
- The accessory dwelling unit is detached from the primary structure
- Not all of these are true:
- None of these is true:
- The accessory dwelling unit is detached from the primary structure
- All of these are true:
- The accessory dwelling unit is detached from the primary structure
- The detached accessory dwelling unit is proposed as an addition over an existing accessory structure
- All of these are true:
- The accessory dwelling unit is detached from the primary structure
- The detached accessory dwelling unit is proposed as an addition over an existing accessory structure
- All of these are true:
- The F1 development area the site is in is one of da_i, da_iii, da_iv
- The accessory dwelling unit is detached from the primary structure
- All of these are true:
- The F1 development area the site is in is da_ii
- The accessory dwelling unit is detached from the primary structure
- Each dwelling unit extends from the foundation to the ceiling and has separate front or rear exterior access to the ground floor