CC · Community Center (CC)
Battle Ground, WA · BGMC 17.118 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Residences of all types, when located on upper floors of commercial buildings | — | ||||
| Live/work | — | ||||
| Group living (seven or more residents) | — | — | — | — | Home✓ ADU— |
| Co-living housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Emergency housing | — | — | — | — | Home✓ ADU— |
| Emergency shelter | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 3,000 sq ft BGMC 17.118.030 | |
| Minimum frontage | 30 ft BGMC 17.118.030 | |
| Maximum residents | Reasonable occupancy, spacing, and intensity of use requirements shall be reviewed under a site plan review process pursuant to Chapter 17.143 BGMC. BGMC 17.135.200(B) | Not set BGMC 17.118.030
for Group living (seven or more residents) (group living); Co-living housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum front setback | 10 ft BGMC 17.118.030 | |
| Side setback |
|
|
| Rear setback |
|
|
| Building separation | 0 ft BGMC 17.118.030 | |
| Maximum height | 45 ft BGMC 17.118.030 | |
| Maximum lot coverage | Maximum determined by compliance with screening and buffering standards contained in Chapter 17.131 BGMC, Table 17.131-1, parking and loading standards of Chapter 17.133 BGMC, the stormwater control ordinance (Chapter 18.250 BGMC) and all other applicable standards. BGMC 17.118.030 | |
| Minimum parking | The live/work unit shall be required to provide parking in accordance with Chapter 17.133 BGMC. Shared parking between users of same or abutting properties shall occur wherever possible. BGMC 17.135.095(C)(5); 17.133.040(D) | 2 spaces per unit BGMC 17.133.040 Table 17.133-1
for Residences of all types, when located on upper floors of commercial buildings (1, 2 units)1 1.5 spaces per unit BGMC 17.133.040 Table 17.133-1
for Residences of all types, when located on upper floors of commercial buildings (3, 4+ units)1 beds in the project ÷ 3 spaces BGMC 17.133.040 Table 17.133-1
for Group living (seven or more residents) (group living) for Co-living housing (group living) Special uses or those not specifically listed in Table 17.133-1 shall provide an adequate number of parking spaces as determined by the planning director or hearing examiner. BGMC 17.133.040(D)
for Transitional housing (group living); Emergency housing (group living); Emergency shelter (group living) |
| Minimum open space | 20% BGMC 17.118.030 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat (two lots) BGMC 16.115.040(A)(1); 16.105.030(C) | A | 2 to 2 BGMC 16.110.010; 16.115.040(A)(1) | — | Minimum lot size 3,000 sq ft BGMC 17.118.030 Minimum frontage 30 ft BGMC 17.118.030 |
| Short plat (three to nine lots) / short subdivision BGMC 16.115.040(A)(2); 16.105.030(C) | A | 3 to 9 BGMC 16.110.010; 16.115.040(A)(2) | — | Minimum lot size 3,000 sq ft BGMC 17.118.030 Minimum frontage 30 ft BGMC 17.118.030 |
| Subdivision (ten or more lots) BGMC 16.115.040(A)(3); 16.105.030(B) | H | 10 or more BGMC 16.110.010; 16.115.040(A)(3) | — | Minimum lot size 3,000 sq ft BGMC 17.118.030 Minimum frontage 30 ft BGMC 17.118.030 |
| Binding site plan BGMC 17.143.035(A) | A | Maximum lots Not set BGMC 17.143.035 |
— | Minimum lot size 3,000 sq ft BGMC 17.118.030 Minimum frontage 30 ft BGMC 17.118.030 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The residences are on upper floors of a commercial building
- The ground floor is 100% commercial or office use along any street frontage for a depth of at least 20 feet
- The ground floor of the live/work unit is used for nonresidential purposes
- None of these is true:
- The yard abuts a residential district (the setback applies on that side only)
- The yard abuts a residential district (the setback applies on that side only)
- None of these is true:
- Co-living units are created by converting an existing building
- Co-living units are created by converting an existing building