DUC HW 125 · DUC H-W Health and Wellness District
Auburn, WA · ACC 18.29 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Supportive housing (permanent) | — | ||||
| Transitional housing | — | ||||
| Middle housing subject to the provisions in Chapter 18.25 ACC (2 to 6 units) | — | — | |||
| Apartments (7 units or more) | — | — | — | — | |
| Mixed-use development | — | — | — | — | |
| Live/work unit, as part of a mixed-use development | — | — | — | — | |
| Work/live unit, as part of a mixed-use development | — | — | — | — | |
| Senior housing | — | — | — | — | |
| Adult family home | — | — | — | — | |
| Communal residence | — | — | — | — | |
| Foster care homes | — | — | — | — | |
| Group residence facilities (6 or fewer residents) | — | — | — | — | |
| Group residence facilities (7 or more residents) | — | — | — | — | |
| Residential care facilities including but not limited to assisted living facilities, convalescent homes, continuing care retirement facilities | — | — | — | — | |
| Nursing homes | — | — | — | — | |
| Assisted living facility | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Indoor emergency housing or shelter | — | — | — | — | |
| Indoor emergency housing or shelter | — | — | — | — | |
| Youth community support facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set ACC 18.29.060(A) | 7 units ACC 18.04.040; 18.04.010; 18.07.020
for Apartments (7 units or more) (4+ units)2 |
| Minimum lot size | 0 sq ft ACC 18.29.060(A)(1) | |
| Minimum lot width | 0 ft ACC 18.29.060(A)(2) | |
| Minimum lot depth | 0 ft ACC 18.29.060(A)(3) | |
| Maximum residents | Not set ACC 18.29.060(A) | 6 persons ACC 18.04.010
4 persons ACC 18.04.060
for Foster care homes (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum height | ||
| Minimum stories | 2 stories ACC 18.29.060(A)(6) | |
| Maximum floor area ratio | ||
| Minimum parking | Parking requirements for uses not listed shall be determined by a study of parking demand for that use, as prepared by a qualified professional and as accepted by the director. ACC 18.29.060(G)(2)(a) | for Middle housing subject to the provisions in Chapter 18.25 ACC (2 to 6 units) (2, 3, 4+ units)2 0.5 spaces per unit ACC 18.29.060(G)(2)
0 spaces per unit ACC 18.29.060(G)(2)
for Senior housing (4+ units)2 |
| Maximum unit size | Not set ACC 18.29.060(A) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 × main dwelling units on the lot units ACC 18.32.010(B) | |
| Minimum lot size | 0 sq ft ACC 18.32.010(B); 18.29.060(A)(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft ACC 18.32.010(D) | |
| Attached to the main house | Not required ACC 18.32.010(C) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision ACC 17.09.060(A) | A12 | up to 9 ACC 17.09.010(A) | — | Minimum lot size 0 sq ft ACC 18.29.060(A)(1) |
| Subdivision ACC 17.10.030; 17.10.050(A) | H | 10 or more ACC 17.01.020; 17.04.380; 17.09.010(A) | — | Minimum lot size 0 sq ft ACC 18.29.060(A)(1) |
| Binding site plan ACC 17.24.020(A)-(B) | A13 | — | — | Minimum lot size 0 sq ft ACC 18.29.060(A)(1) |
| Unit lot subdivision ACC 17.27.025(A); 17.09.060(A)Only for: Middle housing subject to the provisions in Chapter 18.25 ACC (2 to 6 units) | A14 | up to 9 ACC 17.27.025(A); 17.09.010(A) | Minimum parent area 0 sq ft ACC 18.29.060(A)(1); 17.27.020 |
Minimum lot size Not set ACC 17.27.030 |
| Unit lot subdivision ACC 17.27.025(A); 17.10.030Only for: Middle housing subject to the provisions in Chapter 18.25 ACC (2 to 6 units) | H14 | 10 or more ACC 17.27.025(A); 17.01.020; 17.04.380 | Minimum parent area 0 sq ft ACC 18.29.060(A)(1); 17.27.020 |
Minimum lot size Not set ACC 17.27.030 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- Any of these is true:
- Main dwelling units on the lot is at most 100
- No other permanent supportive housing, transitional housing, emergency housing or shelter is within 500 feet of the property lines
- Any of these is true:
- None of these is true:
- A building frontage of the project faces Main Street
- Ground floor retail, restaurant and/or office use along all building frontages facing Main Street
- None of these is true:
- Residential is part of a vertical mixed-use development with medical as the primary development use
- Any of these is true:
- All of these are true:
- Any of these is true:
- None of these is true:
- A building frontage of the project faces Main Street
- Ground floor retail, restaurant and/or office use along all building frontages facing Main Street
- None of these is true:
- Residential is part of a vertical mixed-use development with medical as the primary development use
- Any of these is true:
- All of these are true:
- The development integrates residential use with one or more nonresidential uses (mixed-use development)
- Any of these is true:
- None of these is true:
- A building frontage of the project faces Main Street
- Ground floor retail, restaurant and/or office use along all building frontages facing Main Street
- None of these is true:
- Residential is part of a vertical mixed-use development with medical as the primary development use
- All of these are true:
- Any of these is true:
- All of these are true:
- Beds in the project is at most 100
- Sleeping units in the project is at most 100
- No other permanent supportive housing, transitional housing, emergency housing or shelter is within 500 feet of the property lines
- All of these are true:
- Any of these is true:
- None of these is true:
- A building frontage of the project faces Main Street
- Ground floor retail, restaurant and/or office use along all building frontages facing Main Street
- None of these is true:
- Residential is part of a vertical mixed-use development with medical as the primary development use
- Any of these is true:
- All of these are true:
- Residential is part of a vertical mixed-use development with medical as the primary development use
- The site is within 500 feet walking distance of a transit stop and connected to it by sidewalks or an approved pedestrian facility
- None of these is true:
- The project contributes to a public park or cultural facility to exceed maximum FAR and building height by up to 25%
- The project contributes to a public park or cultural facility to exceed maximum FAR and building height by up to 25%
- None of these is true:
- The project provides bonus features to increase floor area ratio
- The project contributes to a public park or cultural facility to exceed maximum FAR and building height by up to 25%
- All of these are true:
- The project provides bonus features to increase floor area ratio
- The project contributes to a public park or cultural facility to exceed maximum FAR and building height by up to 25%
- The lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The original tract was created by a short subdivision within the previous five years
- Any of these is true:
- The development integrates residential use with one or more nonresidential uses (mixed-use development)
- The land is divided for condominiums under Chapter 64.32 or 64.34 RCW
- No dwelling unit is stacked on another dwelling unit or other use