HC · Highway commercial
Arlington, WA · AMC 20.36.020(a); 20.36.020(e) · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-Family Residence, Detached | — | — | — | — | |
| Multi-Family Rowhouses | — | — | |||
| Multi-Family Apartments | — | — | — | ||
| Multi-Family Courtyard Apartments | — | — | — | ||
| Multi-Family Townhouses | — | — | — | ||
| Multi-Family Use Above a Permitted Non-Residential Use (Mixed Use) | — | — | — | ||
| Multi-Family Use Horizontal to a Permitted Non-Residential Use (Mixed Use) | — | — | — | ||
| Multi-Family Fourplex | — | — | — | — | |
| Co-Living Housing | — | — | — | — | |
| Adult Family Homes (6 or fewer adults) | — | — | — | — | |
| Emergency Housing | — | — | — | — | |
| Emergency Shelter | — | — | — | — | |
| Permanent Supportive Housing | — | — | — | — | |
| Special Needs Childcare Homes | — | — | — | — | |
| Transitional Housing | — | — | — | — | |
| Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions | — | — | — | — | |
| Institutions (other than Halfway Houses) for Confined Mentally Ill Persons | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set AMC 20.110.014(c) | 4 units AMC 20.08.010
for Multi-Family Fourplex (4+ units)3 |
| Minimum units | Not set AMC 20.110.014(c) | 4 units AMC 20.08.010
for Multi-Family Fourplex (4+ units)3 |
| Minimum lot size | Not set AMC 20.110.014(c); 20.48.100 Table 20.48-1 | No limit AMC 20.48.100 Table 20.48-1 footnote 7
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum lot width | The lot size standards for each building type are codified in the transect zones. (See Subsection (c), Place types). The lot size designates the range of lot sizes on which the given building type is allowed to be built. If the lot is smaller or larger than the allowed lot size, a different building type shall be selected. AMC 20.110.014(e)(1); 20.110.014(c)(3) Lot Dimension | 70 ft AMC 20.48.030(a)(4); 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum lot depth | The lot size standards for each building type are codified in the transect zones. (See Subsection (c), Place types). The lot size designates the range of lot sizes on which the given building type is allowed to be built. If the lot is smaller or larger than the allowed lot size, a different building type shall be selected. AMC 20.110.014(e)(1); 20.110.014(c)(3) Lot Dimension | Not set AMC 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum frontage | Not set AMC 20.110.014(c) | for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum density | 15 units per acre AMC 20.110.014(a)(4) | Not set AMC 20.110.014(a)(4)
for Co-Living Housing (group living)27; Adult Family Homes (6 or fewer adults) (group living)27; Emergency Housing (group living)27; Emergency Shelter (group living)27; Permanent Supportive Housing (group living)27; Special Needs Childcare Homes (group living)27; Transitional Housing (group living)27; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Maximum density | Not set AMC 20.48.020(a); 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Maximum residents | Not set AMC 20.08.010 | 6 persons AMC 20.40.120; 20.08.010
for Adult Family Homes (6 or fewer adults) (group living)27 who as a group meet the definition for a family AMC 20.08.010
for Special Needs Childcare Homes (group living)27 |
| Maximum sleeping units | Not set AMC 20.08.010 |
for Co-Living Housing (group living)27 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft AMC 20.110.014(c)(3) Building Placement
for Single-Family Residence, Detached (1 unit)1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Maximum front setback | 20 ft AMC 20.110.014(c)(3) Building Placement
for Single-Family Residence, Detached (1 unit)1 Not set AMC 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Side setback | Not set AMC 20.110.014(c)(3) Building Placement
for Single-Family Residence, Detached (1 unit)1 for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Street side setback | 10 ft AMC 20.110.014(c)(3) Building Placement
for Single-Family Residence, Detached (1 unit)1; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Rear setback | 15 ft AMC 20.110.014(c)(3) Building Placement
for Single-Family Residence, Detached (1 unit)1 for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Building separation | Not set AMC 20.110.014(c) | 10 ft AMC 20.46.075(a)(1)
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Maximum height | Not set AMC 20.110.014(c) | 50 ft AMC 20.48.060(b); 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Maximum stories |
|
2 stories AMC 20.110.014(c)(3) Building Form
for Single-Family Residence, Detached (1 unit)1 Not set AMC 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum height | Not set AMC 20.110.014(c)(3) Building Form
for Single-Family Residence, Detached (1 unit)1; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Minimum stories | Not set AMC 20.110.014(c)(3) Building Form
for Single-Family Residence, Detached (1 unit)1; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 | |
| Maximum lot coverage | Not set AMC 20.110.014(c); 20.48.100 Table 20.48-1 | 100% AMC 20.48.064(a); 20.48.100 Table 20.48-1
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Minimum parking | 2 spaces per unit AMC 20.72.010(f) Table 20.72-1
for Single-Family Residence, Detached (1 unit)1 for Multi-Family Rowhouses (2, 3 units)3; Multi-Family Townhouses (3 units)3; Multi-Family Fourplex (4+ units)3; Multi-Family Rowhouses (4+ units)5; Multi-Family Rowhouses (4+ units)6; Multi-Family Rowhouses (4+ units)7; Multi-Family Townhouses (4+ units)5; Multi-Family Townhouses (4+ units)6; Multi-Family Townhouses (4+ units)7 for Co-Living Housing (group living)27 0.5 spaces per bed AMC 20.72.010(f) Table 20.72-1
0.1 spaces per bed AMC 20.72.010(f) Table 20.72-1
0.3 spaces per bed AMC 20.72.010(f) Table 20.72-1
| |
| Minimum open space | 5% AMC 20.110.014(h)(4)(G) | 10% AMC 20.52.030(a)
for Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)29; Nursing Care Institutions, Intermediate Care Institutions, Handicapped or Infirm Institutions, Childcare Institutions (group living)30; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)29; Institutions (other than Halfway Houses) for Confined Mentally Ill Persons (group living)30 |
| Maximum units per building | Each lot shall only have one building type, except as follows: AMC 20.110.014(e)(2); 20.110.014(e) | 4 units AMC 20.08.010
for Multi-Family Fourplex (4+ units)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units AMC 20.44.042(c)(4); 20.110.014(a)(9) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft AMC 20.110.014(c)(3) Building Placement | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft AMC 20.44.042(c)(6) | |
| Attached to the main house | Not required AMC 20.44.042(c)(4) | |
| Owner lives on site | Not required AMC 20.44.042(c)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short AMC 20.16.220-1; 20.16.400 | A | up to 9 AMC 20.08.010; 20.16.220-1 | — | Minimum lot width
Minimum lot depth
Minimum frontage Maximum units per lot Not set AMC 20.16.400; 20.48.100 Table 20.48-1 |
| Subdivision, major AMC 20.16.220-1; 20.16.400 | H | 10 or more AMC 20.08.010 | — | Minimum lot width
Minimum lot depth
Minimum frontage Maximum units per lot Not set AMC 20.16.400; 20.48.100 Table 20.48-1 |
| Binding site plan AMC 20.16.220-1; 20.16.435(a) | A84 | up to 9 AMC 20.08.010 | — | Minimum lot width
Minimum lot depth
Minimum frontage Maximum units per lot Not set AMC 20.16.400; 20.48.100 Table 20.48-1 |
| Binding site plan AMC 20.16.220-1; 20.16.435(a) | A84 | 10 or more AMC 20.08.010 | — | Minimum lot width
Minimum lot depth
Minimum frontage Maximum units per lot Not set AMC 20.16.400; 20.48.100 Table 20.48-1 |
| Subdivision, unit lot AMC 20.16.220-1; 20.44.020A(b)Only for: Multi-Family Townhouses, Multi-Family Rowhouses | A84 | up to 9 AMC 20.08.010; 20.16.220-1 | — | Minimum lot size No limit AMC 20.44.020B Minimum lot width No limit AMC 20.44.020B Minimum lot depth No limit AMC 20.44.020B Minimum frontage No limit AMC 20.44.020B Maximum units per lot Not set AMC 20.44.020B |
| Subdivision, unit lot AMC 20.16.220-1; 20.44.020A(b)Only for: Multi-Family Townhouses, Multi-Family Rowhouses | H84 | 10 or more AMC 20.08.010; 20.16.220-1 | — | Minimum lot size No limit AMC 20.44.020B Minimum lot width No limit AMC 20.44.020B Minimum lot depth No limit AMC 20.44.020B Minimum frontage No limit AMC 20.44.020B Maximum units per lot Not set AMC 20.44.020B |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are located above a permitted non-residential use in the same building
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- All of these are true:
- Main dwelling units on the lot is less than 30
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 30
- Main dwelling units on the lot is less than 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- Main dwelling units on the lot is at least 100
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The dwelling units are built horizontal to (beside) a permitted non-residential use in the same project
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- All of these are true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The project builds its required commercial portion (commercial/retail on the first floor of street frontage buildings) concurrently with the residential portion
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- All of these are true:
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The building(s), including accessory structures, total thirty thousand square feet or more
- All of these are true:
- The building(s), including accessory structures, total thirty thousand square feet or more
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The lot fronts on the bulb of a cul-de-sac
- None of these is true:
- The lot fronts on the bulb of a cul-de-sac
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is not one of rpz, isz, itz, osz, ssz
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is rpz
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is isz
- The Airport Protection District safety zone the lot is in (rpz = Runway Protection Zone 1, isz = Inner Safety Zone 2, itz = Inner Turning Zone 3, osz = Outer Safety Zone 4, ssz = Sideline Safety Zone 5, outside = none of these) is one of itz, osz, ssz
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, uc_t5_ms, uc_t5_f
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4n_sv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of vc_t4n_mv, uc_t5n_lv
- The lot has two immediately adjacent primary buildings whose average front setback can be used
- All of these are true:
- The building is larger than 10,000 square feet
- The lot has two immediately adjacent primary buildings whose average front setback can be used
- None of these is true:
- The lot has two immediately adjacent primary buildings whose average front setback can be used
- The building is larger than 10,000 square feet
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_f, uc_t5_ms, uc_t5_f
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is vc_t4_ms
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of vc_t4n_sv, vc_t4n_mv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is uc_t5n_lv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, vc_t4_ms, uc_t5_ms, uc_t5_f
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_f, vc_t4_f, vc_t4n_mv, uc_t5n_lv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is cc_t4n_mv
- The lot line is a common boundary with a lot in the RMC, R-Mod, RLC, or RULC zone (the 30-foot setback applies along that line)
- None of these is true:
- The lot line is a common boundary with a lot in the RMC, R-Mod, RLC, or RULC zone (the 30-foot setback applies along that line)
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_mv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of uc_t5_ms, uc_t5_f, uc_t5n_lv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, vc_t4_ms, vc_t4_f
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_f, cc_t4n_mv, vc_t4n_mv
- All of these are true:
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is uc_t5_ms
- The project qualifies for the footnote 3 extra story (an affordable housing development, a LEED certified building, or civic space of the same square footage on-site or the fee in-lieu)
- All of these are true:
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is uc_t5_ms
- The project qualifies for the footnote 3 extra story (an affordable housing development, a LEED certified building, or civic space of the same square footage on-site or the fee in-lieu)
- All of these are true:
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of uc_t5_f, uc_t5n_lv
- The project qualifies for the footnote 3 extra story (an affordable housing development, a LEED certified building, or civic space of the same square footage on-site or the fee in-lieu)
- All of these are true:
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of uc_t5_f, uc_t5n_lv
- The project qualifies for the footnote 3 extra story (an affordable housing development, a LEED certified building, or civic space of the same square footage on-site or the fee in-lieu)
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_ms, cc_t4_f, cc_t4n_mv, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of vc_t4_ms, vc_t4_f
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is cc_t4_ms
- The place type and transect the mixed-use regulating plan assigns to the lot (nc = neighborhood corridor, cc = community center, vc = village center, uc = urban center, sd1/sd2 = special districts, none = no place type) is one of cc_t4_f, cc_t4n_mv, vc_t4_ms, vc_t4_f, vc_t4n_sv, vc_t4n_mv, uc_t5_ms, uc_t5_f, uc_t5n_lv
- The units are senior units only
- All of these are true:
- Bedrooms in one unit is at most 1
- The units are senior units only
- All of these are true:
- Bedrooms in one unit is at least 2
- Bedrooms in one unit is less than 3
- The units are senior units only
- All of these are true:
- Bedrooms in one unit is at least 3
- The units are senior units only
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- The lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- The lot is within one-half mile walking distance of a major transit stop
- The ADU abuts and is served by an alley
- None of these is true:
- The ADU abuts and is served by an alley
- All of these are true:
- The ADU is detached from the primary housing unit (an accessory structure)
- The ADU abuts and is served by an alley
- None of these is true:
- The ADU abuts and is served by an alley
- The ADU is detached from the primary housing unit (an accessory structure)
- The height of the principal unit is less than twenty-four feet
- None of these is true:
- The height of the principal unit is less than twenty-four feet
- The ADU is detached from the primary housing unit (an accessory structure)
- None of these is true:
- The ADU is detached from the primary housing unit (an accessory structure)
- Any of these is true:
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- A restrictive covenant is recorded that the ADU shall be rented at sixty percent AMI or less for fifty years
- Parking is available on an abutting public street
- All of these are true:
- Lot area is less than 6,000 sf
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- A restrictive covenant is recorded that the ADU shall be rented at sixty percent AMI or less for fifty years
- Parking is available on an abutting public street
- All of these are true:
- Lot area is more than 6,000 sf
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- A restrictive covenant is recorded that the ADU shall be rented at sixty percent AMI or less for fifty years
- Parking is available on an abutting public street
- All of these are true:
- Lot area is 6,000 sf
- The lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- A restrictive covenant is recorded that the ADU shall be rented at sixty percent AMI or less for fifty years
- Parking is available on an abutting public street
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- None of these is true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- None of these is true:
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone
- The lot fronts on the bulb of a cul-de-sac
- All of these are true:
- The lot fronts on the bulb of a cul-de-sac
- The owner chooses to develop under the mixed-use development regulations (AMC 20.110) instead of the underlying zone