Sign in

NFR, Neighborhood Family Residential · NFR neighborhood family residential zone

Airway Heights, WA · AHMC 17.06 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family detached
Home✓ ADU✓
————
Manufactured home
Home✓1 ADU✓1
————
Dwelling, single-family attached
Home✓ ADU✓
————
Dwelling, townhouse unit
Home✓ ADU✓
————
Residential conversions of existing nonresidential buildings
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
Home✓2 ADU✓2
—
Dwelling, duplex—
Home✓ ADU✓
———
Dwelling, stacked flat—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, courtyard apartments—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, cottage housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, middle housing—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, triplex——
Home✓ ADU✓
——
Dwelling, townhouses——
Home✓ ADU✓
Home✓ ADU✓
—
Dwelling, fourplex———
Home✓ ADU✓
—
Manufactured (mobile) home park———
HomeH ADU—
—
Adult family home————
Home✓ ADU✓
Group home————
HomeH ADU✓
Convalescent center or nursing home————
HomeH ADU—
Dormitory————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set AHMC 17.06.070
4 units AHMC 17.04.040
for Dwelling, fourplex (4+ units); Dwelling, courtyard apartments (4+ units)
Minimum unitsNot set AHMC 17.06.070
2 units AHMC 17.27.040(B)
for Manufactured (mobile) home park (4+ units)
Minimum lot size
  • No limit3 AHMC 17.17.110
  • 6,000 sq ft4 AHMC 17.06.080
6,000 sq ft AHMC 17.06.080
for Manufactured (mobile) home park (4+ units)
Minimum lot width
  • 30 ft3 AHMC 17.17.120
  • Not set4 AHMC 17.06.080
Not set AHMC 17.06.080
for Manufactured (mobile) home park (4+ units)
Minimum frontage
  • 30 ft3 AHMC 17.17.120
  • 60 ft4 AHMC 17.06.080
60 ft AHMC 17.06.080
for Manufactured (mobile) home park (4+ units)
Maximum density1 unit per the smallest of 1,980, lot area ÷ 3 sq ft, ADUs included AHMC 17.06.070
  • 1 unit per (the smallest of 1,980, lot area ÷ 3) ÷ 1.5 sq ft, ADUs included5 AHMC 17.06.070; 17.06.030(K)(2)
  • 1 unit per the smallest of 1,980, lot area ÷ 3 sq ft, ADUs included6 AHMC 17.06.070
for Residential conversions of existing nonresidential buildings (1, 2, 3, 4+ units)2
1 unit per 3,600 sq ft AHMC 17.27.040(C)
for Manufactured (mobile) home park (4+ units)
Not set AHMC 17.06.070
for Adult family home (group living); Group home (group living); Convalescent center or nursing home (group living); Dormitory (group living)
Minimum development sizeNot set AHMC 17.06.080
217,800 sq ft AHMC 17.27.040(B)
for Manufactured (mobile) home park (4+ units)
Maximum residentsNot set AHMC 17.06.070
  • 8 persons7 AHMC 17.04.010
  • 6 persons8 AHMC 17.04.010
for Adult family home (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 10 ft3 AHMC 17.17.130(A)
  • 10 ft9 AHMC 17.06.090(A)(4)
  • 10 ft10 AHMC 17.06.090(A)(1)
  • 20 ft11 AHMC 17.06.090(A)(1)
  • 50 ft12 AHMC 17.27.050(B)
  • 25 ft13 AHMC 17.27.050(B)
for Manufactured (mobile) home park (4+ units)
Side setback5 ft AHMC 17.06.090(A)(3)
10 ft AHMC 17.27.050(B)
for Manufactured (mobile) home park (4+ units)
Street side setback
  • Corner side yard facing a street or public way, the setback is zero feet except, if parking or a structure which includes parking is located within the side yard, then the setback is 20 feet from the side property line.3 AHMC 17.17.130(C)
  • 10 ft4 AHMC 17.06.090(A)(4)
25 ft AHMC 17.27.050(B)
for Manufactured (mobile) home park (4+ units)
Rear setback
  • Setback can be zero feet for lots adjacent to alleyways or a private or public access roadway, except, if parking or a structure which includes parking is located in the rear yard area of the lot, then the setback is 20 feet from the rear property line. Setbacks for lots which do not have an alleyway are required to be a minimum of five feet to property line.3 AHMC 17.17.130(B)
  • 10 ft4 AHMC 17.06.090(A)(2)
10 ft AHMC 17.27.050(B)
for Manufactured (mobile) home park (4+ units)
Building separation10 ft AHMC 17.06.090(A)(5)
Maximum height40 ft AHMC 17.06.100(B)
Maximum storiesNot set AHMC 17.06.100
3 stories AHMC 17.04.040
for Dwelling, stacked flat (2, 3, 4+ units)
Maximum lot coverage
  • 60%3 AHMC 17.17.140
  • 50%4 AHMC 17.06.100(A)
50% AHMC 17.06.100(A)
for Manufactured (mobile) home park (4+ units)
Maximum floor area ratio0.8 AHMC 17.06.075(A)
0.5 AHMC 17.06.075(A)
for Dwelling, single-family detached (1 unit); Manufactured home (1 unit)1; Dwelling, single-family attached (1 unit); Dwelling, townhouse unit (1 unit); Residential conversions of existing nonresidential buildings (1 unit)2
0.65 AHMC 17.06.075(A)
for Dwelling, duplex (2 units); Dwelling, stacked flat (2 units); Dwelling, courtyard apartments (2 units); Dwelling, middle housing (2 units); Residential conversions of existing nonresidential buildings (2 units)2
No limit AHMC 17.06.075(D)(1)
for Dwelling, cottage housing (2, 3, 4+ units)
0.95 AHMC 17.06.075(A)
for Dwelling, fourplex (4+ units); Dwelling, courtyard apartments (4+ units)
  • 0.9514 AHMC 17.06.075(A)
  • 1.215 AHMC 17.06.075(A)
for Dwelling, townhouses (4+ units); Dwelling, stacked flat (4+ units); Dwelling, middle housing (4+ units); Residential conversions of existing nonresidential buildings (4+ units)2
Not set AHMC 17.06.075(A)
for Manufactured (mobile) home park (4+ units); Adult family home (group living); Group home (group living); Convalescent center or nursing home (group living); Dormitory (group living)
Minimum parking1 space per unit AHMC 17.21.020 Table 1
0 spaces per unit AHMC 17.06.030(K)(3); 17.21.020 Table 1
for Residential conversions of existing nonresidential buildings (1, 2, 3, 4+ units)2
2 spaces per unit AHMC 17.27.060
for Manufactured (mobile) home park (4+ units)
1 space per staff person, plus 1 space per five residents, plus 1 space per vehicle operated by the facility AHMC 17.21.020 Table 1
for Group home (group living)
0.25 spaces per bed AHMC 17.21.020 Table 1
for Convalescent center or nursing home (group living)
1 space per resident AHMC 17.21.020 Table 1
for Dormitory (group living)
Maximum unit sizeNot set AHMC 17.06.100
1,600 sq ft AHMC 17.06.030(G)(1)
for Dwelling, cottage housing (2, 3, 4+ units)
Maximum building footprint3,200 sq ft AHMC 17.06.100(C)(1)
1,000 sq ft AHMC 17.06.100(C)(2)
for Dwelling, townhouse unit (1 unit)
The maximum building footprint shall not exceed 3,200 square feet for single-family dwellings, side-by-side attached multiplexes with up to four units, stacked flats, and courtyard apartments. AHMC 17.06.100(C)(1)
for Residential conversions of existing nonresidential buildings (1, 2, 3, 4+ units)2; Dwelling, middle housing (2, 3, 4+ units)
For cottage housing, the footprint requirements shall comply with AMHC 17.06.030(F). AHMC 17.06.100(C)(3)
for Dwelling, cottage housing (2, 3, 4+ units)
For townhomes, the maximum building footprint per unit shall not exceed 1,000 square feet. AHMC 17.06.100(C)(2)
for Dwelling, townhouses (3, 4+ units)
Not set AHMC 17.27.040
for Manufactured (mobile) home park (4+ units); Adult family home (group living); Group home (group living); Convalescent center or nursing home (group living); Dormitory (group living)
Minimum open spaceNot set AHMC 17.06.100
20% AHMC 17.06.030(G)(2)
for Dwelling, cottage housing (2, 3, 4+ units)
10% AHMC 17.27.040(D)
for Manufactured (mobile) home park (4+ units)
Maximum units per building6 units AHMC 17.06.100(D)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units AHMC 17.24.020(C); 17.06.070

Building

StandardValueExceptions
Front setback
  • 10 ft16 AHMC 17.06.090(A)(4)
  • 10 ft17 AHMC 17.06.090(A)(1)
  • 20 ft18 AHMC 17.06.090(A)(1)
Side setback5 ft AHMC 17.06.090(A)(3)
Rear setback10 ft AHMC 17.06.090(A)(2)
Maximum height40 ft AHMC 17.06.100(B)
Minimum parking
  • 0 spaces per unit19 AHMC 17.21.020 Table 1
  • 1 space per unit20 AHMC 17.21.020 Table 1
Maximum unit size1,000 sq ft AHMC 17.24.020(D)
Attached to the main houseNot required AHMC 17.24.020(A); 17.04.010; 17.04.040

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision AHMC 16.05.010(B); 16.05.050(A) A up to 9 AHMC 16.05.010(A); 16.05.020(A) —
Minimum lot size
6,000 sq ft AHMC 17.06.080
Minimum frontage
60 ft AHMC 17.06.080
Subdivision AHMC 16.03.050(A) H 10 or more AHMC 16.03.010; 16.03.020(A) —
Minimum lot size
6,000 sq ft AHMC 17.06.080
Minimum frontage
60 ft AHMC 17.06.080
Unit lot subdivision AHMC 16.11.020(A)(1); 16.11.040(A); 16.05.050(A)Only for: Dwelling, single-family detached, Dwelling, duplex, Dwelling, triplex, Dwelling, fourplex, Dwelling, courtyard apartments, Dwelling, townhouses, Dwelling, cottage housing A up to 9 AHMC 16.11.020(A)(1) —
Minimum lot size
Each unit lot's area and width for purposes of subdivision may be as small as the footprint of the building situated upon it, subject to the requirements of the building and fire codes, and utility service or easement requirements (i.e., building footprint plus five feet utility or easement access). AHMC 16.11.030(F)
Planned unit development (PUD) AHMC 17.17.000; 17.17.060(A); 17.06.030(B) H — 22 units per acre, ADUs included AHMC 17.17.100; 17.06.070
Minimum lot size
No limit AHMC 17.17.110
Minimum lot width
30 ft AHMC 17.17.120
Minimum frontage
30 ft AHMC 17.17.120

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The manufactured home is a new manufactured home
    • The manufactured home has at least two fully enclosed parallel sections, each at least 12 feet wide by 36 feet long
  2. The lot has an existing nonresidential building that received a certificate of occupancy at least three years before the permit application to add housing units
  3. The residential units have an approved PUD overlay as provided in Chapter 17.17 AHMC
  4. None of these is true:
    • The residential units have an approved PUD overlay as provided in Chapter 17.17 AHMC
  5. The added housing units are constructed entirely within the existing building envelope
  6. None of these is true:
    • The added housing units are constructed entirely within the existing building envelope
  7. The adult family home has DSHS approval under RCW 70.128.066 to serve up to eight adults
  8. None of these is true:
    • The adult family home has DSHS approval under RCW 70.128.066 to serve up to eight adults
  9. All of these are true:
    • The lot is a corner lot
    None of these is true:
    • The residential units have an approved PUD overlay as provided in Chapter 17.17 AHMC
  10. All of these are true:
    • The lot has alley access
    None of these is true:
    • The residential units have an approved PUD overlay as provided in Chapter 17.17 AHMC
    • The lot is a corner lot
  11. None of these is true:
    • The residential units have an approved PUD overlay as provided in Chapter 17.17 AHMC
    • The lot is a corner lot
    • The lot has alley access
  12. The manufactured home is next to the right-of-way of a state highway
  13. None of these is true:
    • The manufactured home is next to the right-of-way of a state highway
  14. Main dwelling units on the lot is at most 5
  15. Main dwelling units on the lot is at least 6
  16. The lot is a corner lot
  17. All of these are true:
    • The lot has alley access
    None of these is true:
    • The lot is a corner lot
  18. None of these is true:
    • The lot is a corner lot
    • The lot has alley access
  19. The lot is within one-half mile (walking distance) of a major transit stop as defined in RCW 36.70A.696(8)
  20. None of these is true:
    • The lot is within one-half mile (walking distance) of a major transit stop as defined in RCW 36.70A.696(8)