128TH ST E, Puyallup, WA 98373
On MLS · $349,000 · 274 days · Redfin ↗
Lots near here →24,799 sf · 100% outside sensitive areas
- County
- Pierce County
- Parcel ID
- 4320003072
- Assessed land value
- $143,200
- Assessed building value
- $0
- Legal
- Section 09 Township 19 Range 04 Quarter 44 HALF DOLLAR BERRY TRACTS PARCEL B OF DBLR 87-02-13-0358 DESC AS S 160 FT OF E 160 FT TR 255 TOG/W EASE OF REC LESS S 5 FT THEREOF TAKEN FOR ADD R/W FOR 128TH ST E AS PER ETN 668342 OUT OF 307-0 SEG Y-0346
Values are from the county assessor.
- Jurisdiction
- Pierce County
- Zone
- TCtr · Towne Center →
Your lot
- Lot area
- 24,799 sf
- Net area
- 24,799 sf (lot area minus wetland, flood, steep slope)
- Frontage
- 158 ft
- Lot width
- ≈ 158 ft (estimated)
- Lot depth
- ≈ 154 ft (estimated)
✔ You can build (by right)
| 4+ units | Multi-Family Housing Level 1, up to 55 unitsPCC Table 18A.16.010 Only if: Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rentalPCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A. Without these choices: up to 34 units Multi-Family Housing Level 2, up to 55 unitsPCC Table 18A.16.010 Only if: Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rentalPCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A. Only if: Dwelling units are in a mixed-use building above nonresidential activity on the first floorPCC 18A.33.210(D) Senior Housing Level 2, up to 55 unitsPCC Table 18A.16.010 Only if: Whether the project uses the 18A.65 bonus housing units, and for which kind of low-income units is low_income_rentalPCC Table 18A.15.020-1; PCC 18A.15.020(D); 18A.65.050(A)(1); Table 18A.65.050 A. Without these choices: up to 34 units |
Dividing the lot
| Subdivision | ✓ Up to 16 lots · by rightPCC 18F.40.020 How 16 lots are counted ✓ Density 60/acre: net area 24,799 sf allows 34.1 unitsPCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4) ✓ Each new lot of 1,550 sf can hold a home |
| Short subdivision | ✓ Up to 16 lots · administrative reviewPCC 18F.50.040(E) How 16 lots are counted ✓ Density 60/acre: net area 24,799 sf allows 34.1 unitsPCC Table 18A.15.020-1; PCC 18A.15.020(C)(1); 18A.15.020(A)(2); 18A.15.020(A)(4) ✓ Each new lot of 1,550 sf can hold a home |
Counted: only lots that face an existing road.
Not checked: lot shape, and whether the lot was divided in the last 5 years.
| 128th St E | local road | 158 ft |
Source: USGS 3DEP bare-earth elevation (lidar), slope on a 3 m grid.
Check it on the WA DNR Lidar Portal ↗.
1. Soil on the lot
2. What it means for a house
USDA rates every soil on 3 levels, from best to worst.
The soil is very good for this use. Expect good performance and very little upkeep.
USDA text
"Not limited" indicates that the soil has features that are very favorable for the specified use. Good performance and very low maintenance can be expected.
The use: A house of 3 stories or less, with no basement. It sits on concrete footings, about 2 ft deep.
The test: USDA checks soil features for this use, like flooding, ground water and slope. Each feature that limits the use gets a score from 0.01 to 1.00. The worst score sets the rating: 1.00 is very limited, a lower score is somewhat limited, no score is not limited.
USDA text
Dwellings are single-family houses of three stories or less. For dwellings without basements, the foundation is assumed to consist of spread footings of reinforced concrete built on undisturbed soil at a depth of 2 feet or at the depth of maximum frost penetration, whichever is deeper.
USDA rates every soil on 3 levels, from best to worst.
The soil is fair for this use. The limits can be overcome or made smaller with special planning, design or building. Expect fair performance and some upkeep.
USDA text
"Somewhat limited" indicates that the soil has features that are moderately favorable for the specified system. The limitations can be overcome or minimized by special planning, design, or installation. Fair performance and moderate maintenance can be expected.
The use: A shallow system that lets rain water soak into the ground, like a rain garden, a swale or porous paving. It holds 1 inch of rain, and the water should soak in within 24 to 48 hours.
The test: USDA checks soil features for this use, like flooding, ground water and slope. Each feature that limits the use gets a score from 0.01 to 1.00. The worst score sets the rating: 1.00 is very limited, a lower score is somewhat limited, no score is not limited.
USDA text
Shallow Infiltration Systems are a set of Best Management Practices for stormwater management. These systems include pervious pavement, buffer strips, filter strips, and vegetated swales. … The fundamental function of these systems is to hold the runoff generated from an area during a one inch rainfall event. … The water should infiltrate into the surrounding soil in 24 to 48 hours.
- Vegetation establishmentNo limitWorst0.50After digging, plants are harder to grow back. Better topsoil or soil amendments may be needed.
USDA text
Material rated fair can be vegetated and stabilized by modifying one or more properties. Topdressing with better material or applications of soil amendments may be necessary for satisfactory performance.
- Adsorptive capacityNo limitWorst0.25The soil under the system can hold back only a little of the harmful material in rain water. This reason can make the rating somewhat limited, never very limited.
USDA text
Soils having low adsorption lack the ability to attenuate potentially harmful material.
- SlopeNo limitWorst0.04Sloping ground is harder for machines and needs a changed design. Added water can make the slope slide.
USDA text
Soils that are sloping are limited in terms of the stormwater management systems that can be installed. Sloping soils are more difficult to for equipment usage. excessive slope may also be a trigger for mass movement when additional water is added to a part of the landscape.
Source: USDA soil survey (SSURGO). It maps soil at about 1 inch = 1/4 mile, so a soil line can be off by 100 ft or more. For screening only.
USDA: "Onsite investigation may be needed to validate these interpretations and to confirm the identity of the soil on a given site."
Not checked: septic, liquefaction.
Sewer
- Inside UGA
- yes
- Nearest public main
- 424 ft (low pressure: needs a grinder pump)
- Provider
- Pierce County Sewer Division ↗ · (253) 798-4050
Source: WA Urban Growth Areas; city, county and sewer district sewer maps.
The sewer maps have gaps. A main can be there but not on the map. The sewer district decides.
Water
- Water system
- TACOMA WATER DIVISION CITY OF
- Phone
- (253) 502-8384
Source: WA Department of Health service areas. The area shows who serves the lot, not where the pipe is. Ask the water system for the distance to the main and the cost.